Literature DB >> 20970110

Early outcomes of descemet stripping automated endothelial keratoplasty in pseudophakic eyes with anterior chamber intraocular lenses.

Preeya K Gupta1, Anna Bordelon, David T Vroman, Natalie A Afshari, Terry Kim.   

Abstract

PURPOSE: To evaluate complications and clinical outcomes of Descemet stripping automated endothelial keratoplasty in eyes with preexisting anterior chamber intraocular lenses.
DESIGN: Retrospective review.
METHODS: Thirty-one patients who underwent Descemet stripping automated endothelial keratoplasty and who had a preexisting anterior chamber intraocular lens were identified from May 2006 through March 2009. Patient follow-up ranged from a minimum of 1 month up to 30 months. Preoperative and postoperative best spectacle-corrected visual acuity, manifest refraction, comorbid conditions, and complications were recorded. Endothelial cell loss, graft dislocation, graft failure rates were calculated.
RESULTS: The mean age at surgery was 78 ± 9 years (range, 53 to 91 years). All eyes had pseudophakic bullous keratopathy, except 1 patient who had a failed penetrating keratoplasty graft. Excluding those patients with severely limited visual potential because of noncorneal pathologic features, the mean best spectacle-corrected visual acuity improved significantly from 20/200 to 20/400 before surgery to 20/63 at 3 months (P < .0001), 20/60 at 6 months (P = .0006), 20/50 at 12 to 15 months (n = 10; P = .004), and 20/40 between 23 and 30 months (n = 8; median, 25 months; P = .007). The preoperative mean spherical equivalent was -0.3 ± 1.8 diopters compared with -0.15 ± 1.5 diopters after surgery (P = .78). The graft dislocation rate was 13%, and the graft failure rate was 16%. For those patients with endothelial cell density data available, the average endothelial cell loss was 48% at a mean of 14 months.
CONCLUSIONS: Although Descemet stripping automated endothelial keratoplasty surgery in patients with an anterior chamber intraocular lens remains a controversial topic, the visual and anatomic outcomes from this limited study support this approach as a surgical option in selected cases.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20970110     DOI: 10.1016/j.ajo.2010.07.003

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  2 in total

1.  Complications and outcomes of descemet stripping automated endothelial keratoplasty with artisan aphakia intraocular lens implantation.

Authors:  Rong-Mei Peng; Yu-Xin Guo; Yuan Qiu; Yan-Sheng Hao; Jing Hong
Journal:  Int J Ophthalmol       Date:  2018-04-18       Impact factor: 1.779

2.  Complications and management in Descemet's stripping endothelial keratoplasty: analysis of consecutive 430 cases.

Authors:  Samar K Basak; Soham Basak
Journal:  Indian J Ophthalmol       Date:  2014-02       Impact factor: 1.848

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.