Literature DB >> 20969440

Temperature increase beneath etched dentin discs during composite polymerization.

Emine Sirin Karaarslan1, Asli Secilmis, Mehmet Bulbul, Cihan Yildirim, Aslihan Usumez.   

Abstract

OBJECTIVE: The purpose of this in vitro study was to measure the temperature increase during the polymerization of a composite resin beneath acid-etched or laser-etched dentin discs. BACKGROUND DATA: The irradiation of dentin with an Er:YAG laser may have a positive effect on the thermal conductivity of dentin. This technique has not been studied extensively.
MATERIALS AND METHODS: Forty dentin discs (5 mm in diameter and 0.5 or 1 mm in height) were prepared from extracted permanent third molars. These dentin discs were etched with 20% orthophosphoric acid or an Er:YAG laser, and were then placed on an apparatus developed to measure temperature increases. The composite resin was polymerized with a high-intensity quartz tungsten halogen (HQTH) or light-emitting diode unit (LED). The temperature increase was measured under the dentin disc with a J-type thermocouple wire that was connected to a data logger. Five measurements were made for each dentin disc, curing unit, and etching system combination. Differences between the initial and the highest temperature readings were taken, and the five calculated temperature changes were averaged to determine the value of the temperature increase. Statistical analysis was performed with a three-way ANOVA and Tukey HSD tests at a 0.05 level of significance. Further SEM examinations were performed.
RESULTS: The temperature increase values varied significantly, depending on etching systems (p < 0.05), dentin thicknesses (p < 0.05), and curing units (p < 0.05). Temperature increases measured beneath laser-etched discs were significantly higher than those for acid-etched dentin discs (p < 0.05). The HQTH unit induced significantly higher temperature increases than the LED unit (p < 0.05). The LED unit induced the lowest temperature change (5.2°C) in the 1-mm, acid-etched dentin group. The HQTH unit induced the highest temperature change (10.4°C) for the 0.5-mm, laser-etched dentin group.
CONCLUSION: The risk of heat-induced pulpal damage should be taken into consideration during the polymerization of composite resin after laser etching when the dentin thickness is less than 0.5 mm.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20969440     DOI: 10.1089/pho.2009.2713

Source DB:  PubMed          Journal:  Photomed Laser Surg        ISSN: 1549-5418            Impact factor:   2.796


  2 in total

1.  Laser all-ceramic crown removal and pulpal temperature--a laboratory proof-of-principle study.

Authors:  P Rechmann; N C H Buu; B M T Rechmann; F C Finzen
Journal:  Lasers Med Sci       Date:  2015-03-18       Impact factor: 3.161

2.  Effect of high-intensity irradiation from dental photopolymerization on the isolated and superfused vertebrate retina.

Authors:  Mohammad Rassaei; Martin Thelen; Ramzi Abumuaileq; Jürgen Hescheler; Matthias Lüke; Toni Schneider
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-12-22       Impact factor: 3.117

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.