Literature DB >> 20966808

Reinforcement of pancreticojejunostomy using polyglycolic acid mesh and fibrin glue sealant.

Sohei Satoi1, Hideyoshi Toyokawa, Hiroaki Yanagimoto, Tomohisa Yamamoto, Satoshi Hirooka, Rintaro Yui, So Yamaki, Yoichi Matsui, Hynek Mergental, A-Hon Kwon.   

Abstract

OBJECTIVES: To examine whether pressure-tight reinforcement of pancreaticojejunostomy (PJ) using polyglycolic acid (PGA) mesh and fibrin glue sealant can reduce the incidence of postoperative pancreatic fistula (POPF).
METHODS: The study population included 128 consecutive patients who underwent pancreaticoduodenectomy between September 2006 and January 2010. Postoperative mortality and morbidity among 50 patients who underwent reinforcement of PJ anastomosis using PGA mesh and fibrin glue were compared with 78 patients (historical controls).
RESULTS: The 2 groups demonstrated no significant differences in frequencies of overall or septic complications, reoperation, or in-hospital death. No significant difference in the frequency of POPF, delayed gastric emptying, or intra-abdominal abscess was found between groups. There was no difference between the 2 groups in the number of necessary interventions, and no bleeding complications or POPF-related mortality occurred. The median length of postoperative in-hospital stay between the 2 groups was similar: 13 days (range, 8-101 days) versus 14 days (range, 8-61 days). Similar findings were observed in a subgroup analysis consisting of patients with a pancreatic duct diameter smaller than 3 mm.
CONCLUSION: This retrospective single-center study showed that reinforcement of PJ anastomosis using PGA mesh and fibrin glue provided no significant benefit in reducing the frequency of POPF.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 20966808     DOI: 10.1097/MPA.0b013e3181f82f55

Source DB:  PubMed          Journal:  Pancreas        ISSN: 0885-3177            Impact factor:   3.327


  9 in total

1.  A sutureless method for digestive tract reconstruction during pancreaticoduodenectomy in a dog model.

Authors:  Xiaohai Cui; Peng Lei; Shiqi Liu; Xuemin Liu; Zheng Wu; Yi Lv
Journal:  Int J Clin Exp Med       Date:  2015-01-15

Review 2.  Systematic review and meta-analysis of fibrin sealants for patients undergoing pancreatic resection.

Authors:  Lorenzo A Orci; Graziano Oldani; Thierry Berney; Axel Andres; Gilles Mentha; Philippe Morel; Christian Toso
Journal:  HPB (Oxford)       Date:  2013-03-06       Impact factor: 3.647

Review 3.  Fibrin sealants and topical agents in hepatobiliary and pancreatic surgery: a critical appraisal.

Authors:  Erin M Hanna; John B Martinie; Ryan Z Swan; David A Iannitti
Journal:  Langenbecks Arch Surg       Date:  2014-06-02       Impact factor: 3.445

4.  CT-US fusion imaging increases the feasibility of early ultrasound-guided percutaneous intervention of local drug therapy in pancreatic contusion and laceration.

Authors:  Cong Feng; Libo Wang; Sai Huang; Qinrui Xing; Xuan Zhou; Ning Xing; Faqin Lv; Tanshi Li
Journal:  Ann Transl Med       Date:  2021-02

5.  A new feasible technique of mesh-reinforced pancreatojejunostomy and pancreatogastrostomy: retrospective analysis of 61 cases.

Authors:  Xianfa Wang; Ying Xin; Junhai Pan; Nengyun Zhang; Wei Zhou
Journal:  World J Surg Oncol       Date:  2012-06-22       Impact factor: 2.754

6.  The efficacy of polyglycolic acid felt reinforcement in preventing postoperative pancreatic fistula after pancreaticojejunostomy in patients with main pancreatic duct less than 3 mm in diameter and soft pancreas undergoing pancreatoduodenectomy (PLANET-PJ trial): study protocol for a multicentre randomized phase III trial in Japan and Korea.

Authors:  Kazuto Shibuya; Jin-Young Jang; Sohei Satoi; Masayuki Sho; Suguru Yamada; Manabu Kawai; Hongbeom Kim; Song Cheol Kim; Jin Seok Heo; Yoo-Seok Yoon; Joon Seong Park; Ho Kyoung Hwang; Isaku Yoshioka; Toshio Shimokawa; Hiroki Yamaue; Tsutomu Fujii
Journal:  Trials       Date:  2019-08-09       Impact factor: 2.279

7.  2-octyl cyanoacrylate sealing of the pancreatic remnant after distal pancreatectomy - A prospective pilot study.

Authors:  Felix J Hüttner; Pascal Probst; Hannes G Kenngott; Phillip Knebel; Thilo Hackert; Alexis Ulrich; Markus W Büchler; Markus K Diener
Journal:  PLoS One       Date:  2018-10-16       Impact factor: 3.240

8.  Effect of a Polyglycolic Acid Mesh Sheet (Neoveil™) in Thyroid Cancer Surgery: A Prospective Randomized Controlled Trial.

Authors:  Seong Hoon Kim; Jong Hyuk Ahn; Hye Jeong Yoon; Jae Hwan Kim; Young Mi Hwang; Yun Suk Choi; Jin Wook Yi
Journal:  Cancers (Basel)       Date:  2022-08-12       Impact factor: 6.575

9.  Effect of polyglycolic acid mesh for prevention of pancreatic fistula after pancreatectomy: A systematic review and meta-analysis.

Authors:  Wei Zhang; Zhicheng Wei; Xu Che
Journal:  Medicine (Baltimore)       Date:  2020-08-21       Impact factor: 1.817

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.