Literature DB >> 20965832

[An optoelectronic cervical cancer screening system for screening cervical cancer: comparison with cervical cytology].

Xiu-kui He1, Xi-ping Luo, Ling-zhi Mao, Gui-ying Chen, Yun Li, Jiang-yu Zhang.   

Abstract

OBJECTIVE: To study the clinical value of optoelectronic cervical cancer screening system (TruScreen, TS) in the screening of cervical cancer in comparison with cervical cytology test.
METHODS: A total of 392 patients were screened by TS, Pap, TCT, and HPV using the pathological and colposcopical results as the golden standard. The sensitivity, specificity, Kappa value and the area of under ROC of each method and their combinations (parallel tests) were compared.
RESULTS: The sensitivity of TS, Pap, TCT and HPV were 32.2%, 42.2%, 74.4% and 47.8%, with specificity of 96.7%, 93.7%, 78.8% and 84.8% in detecting cervical cancer, respectively. The sensitivity of the parallel tests, namely TCT/HPV, TCT/TS, Pap/TS and HPV/TS were 65.6%, 87.8%, 82.2% and 86.7%, with the specificity of 81.1%, 74.5%, 75.8% and 67.2%, respectively. In light of the areas of under ROC, significant differences were noted between the parallel tests of TS/Pap and TS/TCT (P<0.05), but not between TCT/Pap and TCT/TS (P>0.05); significant differences were found between the parallel tests with TS and those without TS (P<0.05), but not between TS alone and the parallel tests incorporating TS (P>0.05), nor between the 4 parallel tests (P>0.05).
CONCLUSION: As a new modality for early screening of cervical carcinoma, TS offers a means for real-time cancer detection with better diagnostic efficacy than Pap and HPV and equivalent efficacy to TCT. The combination of TS and cytological tests can further enhance the diagnostic accuracy.

Entities:  

Mesh:

Year:  2010        PMID: 20965832

Source DB:  PubMed          Journal:  Nan Fang Yi Ke Da Xue Xue Bao        ISSN: 1673-4254


  2 in total

1.  [LC-MS/MS-based screening of new protein biomarkers for cervical precancerous lesions and cervical cancer].

Authors:  Feng Qiu; Fu Chen; Dongdong Liu; Jianhua Xu; Jingling He; Jujiao Xiao; Longbin Cao; Xianzhang Huang
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2019-01-30

2.  Evaluation of a real-time optoelectronic method in the diagnostics of CIN over four years of observations.

Authors:  Barbara Suchońska; Wanda Gajzlerska-Majewska; Mirosław Wielgoś
Journal:  PLoS One       Date:  2021-02-26       Impact factor: 3.240