Literature DB >> 20964205

Moving target irradiation with fast rescanning and gating in particle therapy.

Takuji Furukawa1, Taku Inaniwa, Shinji Sato, Toshiyuki Shirai, Shinichiro Mori, Eri Takeshita, Kota Mizushima, Takeshi Himukai, Koji Noda.   

Abstract

PURPOSE: In moving target irradiation with pencil beam scanning, the interplay effect between the target motion and the scanned beam is a problem because this effect causes over or under dosage in the target volume. To overcome this, we have studied rescanning using a gating technique.
METHODS: A simulation and experimental study was carried out. In the experiment, we used the fast scanning system developed at the HIMAC to verify the validity of phase controlled rescanning method, in which the time for rescanning irradiation of each slice is matched to the gating duration.
RESULTS: Simulation and experimental results showed that controlling the scan speed to match the respiration cycle with rescans can deliver the blurred dose distribution. In the comparison between the static measurements and the moving measurements with the phase controlled rescanning method, the dose difference was less than 2% for pinpoint chambers in the target volume.
CONCLUSIONS: The simulation and experimental results demonstrated that the phase controlled rescanning method makes it possible to deliver the dose distribution close to the expected one. As an experimental result for 3D irradiation, it was estimated that blurring by the probability density function was not only for a lateral distribution, but also for a distal distribution, even in the lateral rescanning.

Mesh:

Year:  2010        PMID: 20964205     DOI: 10.1118/1.3481512

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  28 in total

1.  Motion mitigation for lung cancer patients treated with active scanning proton therapy.

Authors:  Clemens Grassberger; Stephen Dowdell; Greg Sharp; Harald Paganetti
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

2.  Four-dimensional layer-stacking carbon-ion beam dose distribution by use of a lung numeric phantom.

Authors:  Shinichiro Mori; Motoki Kumagai; Kentaro Miki
Journal:  Radiol Phys Technol       Date:  2015-04-02

3.  Gating window dependency on scanned carbon-ion beam dose distribution and imaging dose for thoracoabdominal treatment.

Authors:  Shinichiro Mori; Masataka Karube; Shigeo Yasuda; Naoyoshi Yamamoto; Hiroshi Tsuji; Tadashi Kamada
Journal:  Br J Radiol       Date:  2017-05-25       Impact factor: 3.039

Review 4.  Current status and future prospects of multi-dimensional image-guided particle therapy.

Authors:  Shinichiro Mori; Silvan Zenklusen; Antje-Christin Knopf
Journal:  Radiol Phys Technol       Date:  2013-02-19

5.  Implementation of a target volume design function for intrafractional range variation in a particle beam treatment planning system.

Authors:  S Mori; T Inaniwa; K Miki; T Shirai; K Noda
Journal:  Br J Radiol       Date:  2014-08-29       Impact factor: 3.039

6.  Effects of a difference in respiratory cycle between treatment planning and irradiation for phase-controlled rescanning and carbon pencil beam scanning.

Authors:  S Mori; T Inaniwa; T Furukawa; S Zenklusen; T Shirai; K Noda
Journal:  Br J Radiol       Date:  2013-07-05       Impact factor: 3.039

Review 7.  Advances in radiotherapy techniques and delivery for non-small cell lung cancer: benefits of intensity-modulated radiation therapy, proton therapy, and stereotactic body radiation therapy.

Authors:  Tejan P Diwanji; Pranshu Mohindra; Melissa Vyfhuis; James W Snider; Chaitanya Kalavagunta; Sina Mossahebi; Jen Yu; Steven Feigenberg; Shahed N Badiyan
Journal:  Transl Lung Cancer Res       Date:  2017-04

8.  Validation of dose distribution for liver tumors treated with real-time-image gated spot-scanning proton therapy by log data based dose reconstruction.

Authors:  Takahiro Yamada; Seishin Takao; Hidenori Koyano; Hideaki Nihongi; Yusuke Fujii; Shusuke Hirayama; Naoki Miyamoto; Taeko Matsuura; Kikuo Umegaki; Norio Katoh; Isao Yokota; Hiroki Shirato; Shinichi Shimizu
Journal:  J Radiat Res       Date:  2021-07-10       Impact factor: 2.724

9.  Scanned carbon beam irradiation of moving films: comparison of measured and calculated response.

Authors:  Christoph Bert; Daniel Richter; Marco Durante; Eike Rietzel
Journal:  Radiat Oncol       Date:  2012-04-02       Impact factor: 3.481

Review 10.  Technological Advances in Charged-Particle Therapy.

Authors:  Jong Min Park; Jung-In Kim; Hong-Gyun Wu
Journal:  Cancer Res Treat       Date:  2021-06-21       Impact factor: 4.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.