Literature DB >> 20964174

Semiautomatic technique for defining the internal gross tumor volume of lung tumors close to liver/spleen cupola by 4D-CT.

Pietro Mancosu1, Roberto Sghedoni, Valentino Bettinardi, Mark Anthony Aquilina, Piera Navarria, Giovanni Mauro Cattaneo, Nadia Di Muzio, Luca Cozzi, Marta Scorsetti.   

Abstract

PURPOSE: It has been shown that in cases of lung tumors close to the liver cupola, the four dimensional (4D)-CT postprocessing maximum intensity projection (MIP) algorithm does not fully recover the radiotherapy internal gross tumor volume (IGTV). In this work, a semiautomatic technique was evaluated by which the residual IGTV that was not included into the IGTV by MIP algorithm was actually added.
METHODS: A moving phantom and five selected patients were considered. The various IGTVs produced by the semiautomatic approach were compared to those generated by 4D-CT manual contouring.
RESULTS: In all cases, the radiation oncologist qualitatively concurred with the semiautomatic IGTV. A quantitative difference in volume of 2.6% was found in the phantom study, whereas a mean difference of 0.1 +/- 4.6% was obtained in the patient studies.
CONCLUSIONS: A semiautomatic technique to include the residual part of IGTV covered by liver/spleen cupola when using MIP algorithm was validated on phantom and on selected patients, revealing the possibility of defining the IGTV for patients with lesions located near liver/spleen cupola by performing only the contours on the MIP series.

Entities:  

Mesh:

Year:  2010        PMID: 20964174     DOI: 10.1118/1.3471379

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Use of combined maximum and minimum intensity projections to determine internal target volume in 4-dimensional CT scans for hepatic malignancies.

Authors:  Jin Liu; Jia-Zhou Wang; Jian-Dong Zhao; Zhi-Yong Xu; Guo-Liang Jiang
Journal:  Radiat Oncol       Date:  2012-01-30       Impact factor: 3.481

2.  Commissioning a four-dimensional Computed Tomography Simulator for minimum target size due to motion in the Anterior-Posterior direction: a procedure and treatment planning recommendations.

Authors:  Marcus Sonier; Brandon Vangenderen; Dallas Visagie; Cameron Appeldoorn; Te-Chih Archie Chiang; Lindsay Mathew; Stefan Reinsberg; Jim Rose; Ramani Ramaseshan
Journal:  J Appl Clin Med Phys       Date:  2020-07-15       Impact factor: 2.102

3.  A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery.

Authors:  Yun Ding; Jianbin Li; Wei Wang; Suzhen Wang; Jinzhi Wang; Zhifang Ma; Qian Shao; Min Xu
Journal:  Radiat Oncol       Date:  2014-03-19       Impact factor: 3.481

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.