Literature DB >> 20963698

Radiological and histopathological comparison of microporous polysaccharide hemospheres and oxidized regenerated cellulose in the rabbit brain: a study of efficacy and safety.

Hakan Emmez1, Mehmet Tonge, Nil Tokgoz, Emre Durdag, Ipek Gonul, Necdet Cevıker.   

Abstract

AIM: Topical hemostatic agents are widely used in brain surgery but they have some disadvantages such as foreign body reaction, being a focus for infection and causing artifacts in radiological examinations. The purpose of this study is to compare the effectiveness and safety of microporous polysaccharide hemospheres (MPH) with a well known agent, oxidized regenerated cellulose (ORC), histopathologically and radiologically.
MATERIAL AND METHODS: Standard brain lesions (4x1mm) were created in 24 hemispheres in 12 New-Zealand rabbits. Animals were divided into three groups; control, ORC and MPH. Twenty-four hours later, all rabbits magnetic resonance brain imaging. After imaging, the animals were sacrificed and the brains were removed for histopathological analysis.
RESULTS: Histopathological analysis showed no significant difference between the groups. Radiological examination showed no significant difference between the MPH and ORC groups in terms of edema but the edema in control group was significantly prominent than MPH and ORC groups (p < 0.001).
CONCLUSION: A new agent (MPH) provides safe and effective hemostasis in the brain in this study. The most important advantage of microporous polysaccharide hemospheres is their rapid clearance from the surgical field and therefore having the potential of causing less imaging artifacts.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20963698     DOI: 10.5137/1019-5149.JTN.3300-10.2

Source DB:  PubMed          Journal:  Turk Neurosurg        ISSN: 1019-5149            Impact factor:   1.003


  3 in total

1.  In vitro evaluation of the hyaluronic acid/alginate composite powder for topical haemostasis and wound healing.

Authors:  Yi-Wen Chen; Chia-Hsin Lu; Meng-Han Shen; Shih-Yeh Lin; Chia-Hui Chen; Ching-Kuang Chuang; Chia-Che Ho
Journal:  Int Wound J       Date:  2019-12-16       Impact factor: 3.315

2.  Comparison of microporous polysaccharide hemospheres and Ankaferd Blood Stopper in a rabbit epistaxis model.

Authors:  Veysel Yurttas; Murat Sereflican; Elçin Hakan Terzi; Gulzade Ozyalvaçlı; Hasan Kazaz
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-06-23       Impact factor: 2.503

Review 3.  A systematic review on the use of topical hemostats in trauma and emergency surgery.

Authors:  Osvaldo Chiara; Stefania Cimbanassi; Giovanni Bellanova; Massimo Chiarugi; Andrea Mingoli; Giorgio Olivero; Sergio Ribaldi; Gregorio Tugnoli; Silvia Basilicò; Francesca Bindi; Laura Briani; Federica Renzi; Piero Chirletti; Giuseppe Di Grezia; Antonio Martino; Rinaldo Marzaioli; Giuseppe Noschese; Nazario Portolani; Paolo Ruscelli; Mauro Zago; Sebastian Sgardello; Franco Stagnitti; Stefano Miniello
Journal:  BMC Surg       Date:  2018-08-29       Impact factor: 2.102

  3 in total