Literature DB >> 20961774

Drug-eluting tibial stents: objective patency determination.

William D McMillan1, Chris D Leville, Troy D Long, Maria Gomes, Jeffery L Groffsky, Scott R Schultz.   

Abstract

PURPOSE: Endovascular management of limb-threatening ischemia often requires treatment of tibial occlusive disease. This study was preformed to examine the patency of drug-eluting tibial stents.
MATERIALS AND METHODS: The medical records of all patients undergoing drug-eluting tibial stent placement for limb-threatening ischemia from June 2004 to June 2008 were retrospectively reviewed. Postprocedural antiplatelet therapy included clopidogrel and aspirin. Patients were followed with serial arterial duplex ultrasonography and had selective subsequent angiographic evaluation based on noninvasive findings. Primary patency of the target lesion, limb salvage, and survival rates were reported.
RESULTS: A total of 240 patients underwent 283 tibial angioplasty procedures to treat limb-threatening ischemia during the 4-year period. Fifty-two patients (22%) had a suboptimal balloon result and were treated with a drug-eluting tibial stent. Balloon-expandable paclitaxel-eluting stents were used in all patients (1.2 stents per patient; range, 1-3; median diameter, 2.75 mm; range, 2.5-3.5 mm; median length, 24 mm; range, 20-32 mm). Forty-eight of those 52 patients (92%) had simultaneous endovascular treatment of proximal lesions. Mean follow-up was 14.3 months (range, 1-48 months). Target lesion patency of the drug-eluting tibial stent was 73% at 24 months (SE < 10%). Limb salvage rate in patients treated with drug-eluting tibial stents was 86% at 26 months (SE < 10%), and the survival rate was 65% at 24 months (SE < 10%).
CONCLUSIONS: Drug-eluting tibial stents are a viable option for the endovascular management of limb-threatening ischemia and have acceptable patency rates. The majority of patients require multilevel endovascular treatment, and close surveillance is required for limb salvage.
Copyright © 2010 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20961774     DOI: 10.1016/j.jvir.2010.09.011

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  3 in total

1.  Proceedings from the Society of Interventional Radiology research consensus panel on critical limb ischemia.

Authors:  Sanjay Misra; Robert Lookstein; John Rundback; Alan T Hirsch; William R Hiatt; Michael R Jaff; Christopher R White; Michael Conte; Patrick Geraghty; Manesh Patel; Kenneth Rosenfield
Journal:  J Vasc Interv Radiol       Date:  2013-04       Impact factor: 3.464

2.  Stent-Apposition Salvage of an Anterior Tibial Artery After Inadvertent Angioplasty Balloon Retention During CTO Revascularization.

Authors:  R Choudry; E Deutsch; J Durinka; T Dhir
Journal:  EJVES Short Rep       Date:  2016-08-09

3.  Comparative performance analysis of interventional devices for the treatment of ischemic disease in below-the-knee lesions: a systematic review and meta-analysis.

Authors:  Emi Kearon Matsuoka; Terumitsu Hasebe; Ryota Ishii; Naoki Miyazaki; Kenzo Soejima; Kiyotaka Iwasaki
Journal:  Cardiovasc Interv Ther       Date:  2021-02-06
  3 in total