Literature DB >> 20959686

Nonlinear least-squares modeling of 3D interaction position in a monolithic scintillator block.

Zhi Li1, M Wedrowski, P Bruyndonckx, G Vandersteen.   

Abstract

This paper presents a study of possible models to describe the relation between the scintillation light point-of-origin and the measured photo detector pixel signals in monolithic scintillation crystals. From these models the X, Y and depth of interaction (DOI) coordinates can be estimated simultaneously by nonlinear least-square fitting. The method depends only on the information embedded in the signals of individual events, and therefore does not need any prior position training or calibration. Three possible distributions of the light sources were evaluated: an exact solid-angle-based distribution, an approximate solid-angle distribution and an extended approximate solid-angle-based distribution which includes internal reflection at side and bottom surfaces. The performance of the general model using these three distributions was studied using Monte Carlo simulated data of a 20 x 20 x 10 mm lutetium oxyorthosilicate (Lu₂SiO₅ or LSO) block read out by 2 Hamamatsu S8550 avalanche photo diode arrays. The approximate solid-angle-based model had the best compromise between resolution and simplicity. This model was also evaluated using experimental data by positioning a narrow 1.2 mm full width at half maximum (FWHM) beam of 511 keV photons at known positions on the 20 x 20 x 10 mm LSO block. An average intrinsic resolution in the X-direction of 1.4 mm FWHM was obtained for positions covering the complete block. The intrinsic DOI resolution was estimated at 2.6 mm FWHM.

Entities:  

Mesh:

Year:  2010        PMID: 20959686     DOI: 10.1088/0031-9155/55/21/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Evaluation of event position reconstruction in monolithic crystals that are optically coupled.

Authors:  M Morrocchi; W C J Hunter; A Del Guerra; T K Lewellen; P E Kinahan; L R MacDonald; M G Bisogni; R S Miyaoka
Journal:  Phys Med Biol       Date:  2016-11-03       Impact factor: 3.609

2.  Combining Surface Treatments with Shallow Slots to Improve the Spatial Resolution Performance of Continuous, Thick LYSO Detectors for PET.

Authors:  M Kaul; S Surti; J S Karp
Journal:  IEEE Trans Nucl Sci       Date:  2013-02-01       Impact factor: 1.679

3.  A layered single-side readout depth of interaction time-of-flight-PET detector.

Authors:  L Bläckberg; S Sajedi; G El Fakhri; H Sabet
Journal:  Phys Med Biol       Date:  2021-02-11       Impact factor: 3.609

4.  First Images of a Three-Layer Compton Telescope Prototype for Treatment Monitoring in Hadron Therapy.

Authors:  Gabriela Llosá; Marco Trovato; John Barrio; Ane Etxebeste; Enrique Muñoz; Carlos Lacasta; Josep F Oliver; Magdalena Rafecas; Carles Solaz; Paola Solevi
Journal:  Front Oncol       Date:  2016-02-02       Impact factor: 6.244

5.  Depth of interaction determination in monolithic scintillator with double side SiPM readout.

Authors:  Matteo Morrocchi; Giovanni Ambrosi; Maria Giuseppina Bisogni; Filippo Bosi; Marco Boretto; Piergiorgio Cerello; Maria Ionica; Ben Liu; Francesco Pennazio; Maria Antonietta Piliero; Giovanni Pirrone; Vasile Postolache; Richard Wheadon; Alberto Del Guerra
Journal:  EJNMMI Phys       Date:  2017-02-16

6.  Optimisation of monolithic nanocomposite and transparent ceramic scintillation detectors for positron emission tomography.

Authors:  Keenan J Wilson; Roumani Alabd; Mehran Abolhasan; Mitra Safavi-Naeini; Daniel R Franklin
Journal:  Sci Rep       Date:  2020-01-29       Impact factor: 4.379

7.  Performance evaluation of side-by-side optically coupled monolithic LYSO crystals.

Authors:  Marta Freire; Sara Echegoyen; Andrea Gonzalez-Montoro; Filomeno Sanchez; Antonio J Gonzalez
Journal:  Med Phys       Date:  2022-06-21       Impact factor: 4.506

  7 in total