Automated cerebrospinal fluid cell counts using the Sysmex XE-5000: is it time for new reference ranges?

Linda M Sandhaus1, Pedro Ciarlini, Diane Kidric, Christine Dillman, Maryann O'Riordan.   

Abstract

The main objectives of the study were to compare manual and automated WBC counts on clear cerebrospinal fluid (CSF) samples. Clear CSF samples from 200 adults and children were studied. Cell counts were performed manually using a hemocytometer and then analyzed on the Sysmex XE-5000. Descriptive statistics and Spearman correlation for nonparametric data were used for method comparison. Manual WBC counts ranged from 0 to 702 cells/μL, and Sysmex counts ranged from 0 to 629 cells/μL. The Spearman rank correlation coefficient for the entire range of data was 0.77 (P < .001); however, the correlation was weaker at the low end of the data spectrum. For manual WBC ranges of 0 to 5 cells/μL and 0 to 10 cells/μL, the corresponding Sysmex 0 to 95th percentile ranges were 0 to 23 cells/μL and 0 to 27 cells/μL, respectively. The results suggest that larger studies are necessary to determine new reference ranges for automated CSF WBC counts.

Entities:  

Mesh:

Year:  2010        PMID: 20959656     DOI: 10.1309/AJCPABGQXSIA4SMT

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  4 in total

Review 1.  Technological features of blast identification in the cerebrospinal fluid: A systematic review of flow cytometry and laboratory haematology methods.

Authors:  John L Frater; Cara Lunn Shirai; Jonathan R Brestoff
Journal:  Int J Lab Hematol       Date:  2022-07-04       Impact factor: 3.450

2.  Use of the Sysmex XT-4000i hematology analyzer in the differentiation of cerebrospinal fluid cells in children.

Authors:  Beata Zelazowska-Rutkowska; Janusz Zak; Malgorzata Wojtkowska; Justyna Zaworonek; Bogdan Cylwik
Journal:  J Clin Lab Anal       Date:  2018-11-28       Impact factor: 2.352

3.  A comparison of the analysis of 3 types of body fluids using the XN-350 hematology analyzer versus light microscopy assessment.

Authors:  Jiwon Lee; Younggeun Cho; Han-Sung Kim; Hee Jung Kang; Miyoung Kim; Young Kyung Lee
Journal:  Medicine (Baltimore)       Date:  2021-03-19       Impact factor: 1.817

4.  Automated Analysis of Cerebrospinal Fluid Cells Using Commercially Available Blood Cell Analysis Devices-A Critical Appraisal.

Authors:  Manfred Wick; Catharina C Gross; Hayrettin Tumani; Brigitte Wildemann; Martin Stangel
Journal:  Cells       Date:  2021-05-18       Impact factor: 6.600

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.