Literature DB >> 20957746

Terahertz in-line sensor for direct coating thickness measurement of individual tablets during film coating in real-time.

Robert K May1, Michael J Evans, Shuncong Zhong, Ian Warr, Lynn F Gladden, Yaochun Shen, J Axel Zeitler.   

Abstract

We present a new in-line measurement technique to determine the coating thickness of individual pharmaceutical tablets during film coating in a pan coating unit using pulsed terahertz technology. Results of these real-time terahertz measurements acquired during a production scale coating run are validated using both off-line high-resolution terahertz pulsed imaging of the whole dosage form as well as weight-gain measurements made on sample tablets removed at discrete time intervals during the process run. The terahertz measurements provide a direct method of determining the coating thickness, and no chemometric calibration models are required for the quantification. The results, and their repeatability, demonstrate that real-time monitoring of pharmaceutical tablet coating is not only possible but also provides substantially more information of the coating quality than the standard quality control method. Rather than providing the average coating thickness of a large number of tablets, the terahertz sensor provides the thickness of up to 100 individual tablet coatings per minute. Using this information, the operator can get additional information about the thickness distribution in the coating pan and adjust the process accordingly. At present, a minimum coating thickness of 40 μm is required to determine the coating thickness. The technique is applicable for coatings up to 1 mm in thickness. Within that range, it provides thickness measurements of sub-micron resolution. Terahertz in-line coating process measurements show considerable potential for applications in real-time release, process analytical technology and quality by design.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Keywords:  analysis; terahertz pulsed imaging; coating; coating thickness; formulation; in-line sensor; process analytical technology; processing; quality by design; unit operations

Mesh:

Substances:

Year:  2010        PMID: 20957746     DOI: 10.1002/jps.22359

Source DB:  PubMed          Journal:  J Pharm Sci        ISSN: 0022-3549            Impact factor:   3.534


  9 in total

1.  Applying terahertz technology for nondestructive detection of crack initiation in a film-coated layer on a swelling tablet.

Authors:  Wataru Momose; Hiroyuki Yoshino; Yoshifumi Katakawa; Kazunari Yamashita; Keiji Imai; Kazuhiro Sako; Eiji Kato; Akiyoshi Irisawa; Etsuo Yonemochi; Katsuhide Terada
Journal:  Results Pharma Sci       Date:  2012-04-13

2.  Evaluation of coating properties of enteric-coated tablets using terahertz pulsed imaging.

Authors:  Masahiro Niwa; Yasuhiro Hiraishi; Katsuhide Terada
Journal:  Pharm Res       Date:  2014-02-27       Impact factor: 4.200

3.  Impact of Processing Conditions on Inter-tablet Coating Thickness Variations Measured by Terahertz In-Line Sensing.

Authors:  Hungyen Lin; Robert K May; Michael J Evans; Shuncong Zhong; Lynn F Gladden; Yaochun Shen; J Axel Zeitler
Journal:  J Pharm Sci       Date:  2015-06-02       Impact factor: 3.534

Review 4.  A Review of Disintegration Mechanisms and Measurement Techniques.

Authors:  Daniel Markl; J Axel Zeitler
Journal:  Pharm Res       Date:  2017-03-01       Impact factor: 4.200

5.  Terahertz Time-Domain Reconstruction of Coating Microstratigraphy on Gilded Surfaces.

Authors:  Ilaria Cacciari; Daniele Ciofini; Hubert Baija; Salvatore Siano
Journal:  Materials (Basel)       Date:  2019-11-21       Impact factor: 3.623

6.  Feasibility of In-line monitoring of critical coating quality attributes via OCT: Thickness, variability, film homogeneity and roughness.

Authors:  Stephan Sacher; Anna Peter; Johannes G Khinast
Journal:  Int J Pharm X       Date:  2020-12-17

7.  Clinical Diagnosis of Gastric Cancer by High-Sensitivity THz Fiber-Based Fast-Scanning Near-Field Imaging.

Authors:  Hua Chen; Juan Han; Shihua Ma; Xiao Li; Tianzhu Qiu; Xiaofeng Chen
Journal:  Cancers (Basel)       Date:  2022-08-15       Impact factor: 6.575

8.  Terahertz pulsed imaging and magnetic resonance imaging as tools to probe formulation stability.

Authors:  Qilei Zhang; Lynn F Gladden; Paolo Avalle; J Axel Zeitler; Michael D Mantle
Journal:  Pharmaceutics       Date:  2013-10-25       Impact factor: 6.321

Review 9.  Review of Terahertz Pulsed Imaging for Pharmaceutical Film Coating Analysis.

Authors:  Décio Alves-Lima; Jun Song; Xiaoran Li; Alessia Portieri; Yaochun Shen; J Axel Zeitler; Hungyen Lin
Journal:  Sensors (Basel)       Date:  2020-03-06       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.