Literature DB >> 20954755

Automated broadband phase correction of Fourier transform ion cyclotron resonance mass spectra.

Feng Xian1, Christopher L Hendrickson, Greg T Blakney, Steven C Beu, Alan G Marshall.   

Abstract

It has been known for 35 years that phase correction of FTICR data can in principle produce an absorption-mode spectrum with mass resolving power as much as a factor of 2 higher than conventional magnitude-mode display, an improvement otherwise requiring a (much more expensive) increase in magnetic field strength. However, temporally dispersed excitation followed by time-delayed detection results in steep quadratic variation of signal phase with frequency. Here, we present a robust, rapid, automated method to enable accurate broadband phase correction for all peaks in the mass spectrum. Low-pass digital filtering effectively eliminates the accompanying baseline roll. Experimental FTICR absorption-mode mass spectra exhibit at least 40% higher resolving power (and thus an increased number of resolved peaks) as well as higher mass accuracy relative to magnitude mode spectra, for more complete and more reliable elemental composition assignments for mixtures as complex as petroleum.

Year:  2010        PMID: 20954755     DOI: 10.1021/ac101091w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  26 in total

1.  Mass resolution and mass accuracy: how much is enough?

Authors:  Alan G Marshall; Greg T Blakney; Tong Chen; Nathan K Kaiser; Amy M McKenna; Ryan P Rodgers; Brian M Ruddy; Feng Xian
Journal:  Mass Spectrom (Tokyo)       Date:  2013-04-15

2.  Elemental composition validation from stored waveform inverse Fourier transform (SWIFT) isolation FT-ICR MS isotopic fine structure.

Authors:  Brian M Ruddy; Gregory T Blakney; Ryan P Rodgers; Christopher L Hendrickson; Alan G Marshall
Journal:  J Am Soc Mass Spectrom       Date:  2013-08-06       Impact factor: 3.109

3.  Application of phase correction to improve the interpretation of crude oil spectra obtained using 7 T Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Yunju Cho; Yulin Qi; Peter B O'Connor; Mark P Barrow; Sunghwan Kim
Journal:  J Am Soc Mass Spectrom       Date:  2013-10-05       Impact factor: 3.109

4.  Unit mass baseline resolution for an intact 148 kDa therapeutic monoclonal antibody by Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Santosh G Valeja; Nathan K Kaiser; Feng Xian; Christopher L Hendrickson; Jason C Rouse; Alan G Marshall
Journal:  Anal Chem       Date:  2011-10-20       Impact factor: 6.986

5.  Quantitative Mass Spectrometry Reveals Changes in Histone H2B Variants as Cells Undergo Inorganic Arsenic-Mediated Cellular Transformation.

Authors:  Matthew Rea; Tingting Jiang; Rebekah Eleazer; Meredith Eckstein; Alan G Marshall; Yvonne N Fondufe-Mittendorf
Journal:  Mol Cell Proteomics       Date:  2016-05-11       Impact factor: 5.911

6.  Phase correction of Fourier transform ion cyclotron resonance mass spectra using MatLab.

Authors:  Yulin Qi; Christopher J Thompson; Steve L Van Orden; Peter B O'Connor
Journal:  J Am Soc Mass Spectrom       Date:  2011-01-28       Impact factor: 3.109

Review 7.  Fourier transform mass spectrometry.

Authors:  Michaela Scigelova; Martin Hornshaw; Anastassios Giannakopulos; Alexander Makarov
Journal:  Mol Cell Proteomics       Date:  2011-07       Impact factor: 5.911

8.  21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer: A National Resource for Ultrahigh Resolution Mass Analysis.

Authors:  Christopher L Hendrickson; John P Quinn; Nathan K Kaiser; Donald F Smith; Greg T Blakney; Tong Chen; Alan G Marshall; Chad R Weisbrod; Steven C Beu
Journal:  J Am Soc Mass Spectrom       Date:  2015-06-20       Impact factor: 3.109

9.  Ion trap with narrow aperture detection electrodes for Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Konstantin O Nagornov; Anton N Kozhinov; Oleg Y Tsybin; Yury O Tsybin
Journal:  J Am Soc Mass Spectrom       Date:  2015-03-14       Impact factor: 3.109

10.  Least-squares fitting of time-domain signals for Fourier transform mass spectrometry.

Authors:  Tagir Aushev; Anton N Kozhinov; Yury O Tsybin
Journal:  J Am Soc Mass Spectrom       Date:  2014-05-01       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.