Literature DB >> 20954593

Correlation among ocular spherical aberration, corneal spherical aberration, and corneal asphericity before and after LASIK for myopic astigmatism with the SCHWIND AMARIS platform.

Samuel Arba Mosquera1, Diego de Ortueta.   

Abstract

PURPOSE: To determine the spherical wave aberration of the human eye based on corneal topography.
METHODS: Based on the pre- and postoperative status of 146 consecutive eyes (median patient age 36 years), the correlations between spherical aberration and asphericity and between corneal and ocular spherical aberrations were determined using simple linear regression methods. The asphericity (Q) values for which spherical aberration equals zero as well as the reference Q values for which corneal spherical aberration equals ocular spherical aberration have been determined. Patients underwent LASIK using the AMARIS excimer laser platform (SCHWIND eye-tech-solutions). All ablations were based on aspheric aberration-neutral profiles.
RESULTS: Corneal and ocular spherical aberrations correlate well with Q value and the value p · R(-3) in patients before and after LASIK for myopic astigmatism. A Q value of -0.19 to -0.27 can provide zero ocular spherical aberration in patients before and after LASIK for myopic astigmatism. Ocular spherical aberration is induced at a rate of half the induced corneal spherical aberration. A reference Q value of -0.12 to +0.01 can provide corneal spherical aberration equal to ocular spherical aberration in patients before and after LASIK for myopic astigmatism.
CONCLUSIONS: Ocular and corneal wave aberrations are two different concepts that are not interchangeable. As for spherical aberration, a simple static model with a reference cornea deviating from a Cartesian oval can provide a 2:1 correspondence between corneal and ocular spherical aberration. Copyright 2011, SLACK Incorporated.

Entities:  

Mesh:

Year:  2010        PMID: 20954593     DOI: 10.3928/1081597X-20101001-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  3 in total

1.  Corneal Spherical Aberration and Corneal Asphericity after Small Incision Lenticule Extraction and Femtosecond Laser-Assisted LASIK.

Authors:  Hui Zhang; Yan Wang; Hua Li
Journal:  J Ophthalmol       Date:  2017-08-27       Impact factor: 1.909

2.  Comparison of visual outcomes after femtosecond laser-assisted LASIK versus flap-off epipolis LASIK for myopia.

Authors:  Junjie Piao; Woong-Joo Whang; Choun-Ki Joo
Journal:  BMC Ophthalmol       Date:  2020-07-29       Impact factor: 2.209

3.  Comparison of Low Degree/High Degree and Zernike Expansions for Evaluating Simulation Outcomes After Customized Aspheric Laser Corrections.

Authors:  Damien Gatinel; Jacques Malet; Laurent Dumas; Dimitri T Azar
Journal:  Transl Vis Sci Technol       Date:  2021-03-01       Impact factor: 3.283

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.