Literature DB >> 20953680

Wireless Body Area Network (WBAN) design techniques and performance evaluation.

Jamil Yusuf Khan1, Mehmet R Yuce, Garrick Bulger, Benjamin Harding.   

Abstract

In recent years interest in the application of Wireless Body Area Network (WBAN) for patient monitoring applications has grown significantly. A WBAN can be used to develop patient monitoring systems which offer flexibility to medical staff and mobility to patients. Patients monitoring could involve a range of activities including data collection from various body sensors for storage and diagnosis, transmitting data to remote medical databases, and controlling medical appliances, etc. Also, WBANs could operate in an interconnected mode to enable remote patient monitoring using telehealth/e-health applications. A WBAN can also be used to monitor athletes' performance and assist them in training activities. For such applications it is very important that a WBAN collects and transmits data reliably, and in a timely manner to a monitoring entity. In order to address these issues, this paper presents WBAN design techniques for medical applications. We examine the WBAN design issues with particular emphasis on the design of MAC protocols and power consumption profiles of WBAN. Some simulation results are presented to further illustrate the performances of various WBAN design techniques.

Entities:  

Mesh:

Year:  2010        PMID: 20953680     DOI: 10.1007/s10916-010-9605-x

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  3 in total

1.  Energy efficient medium access protocol for wireless medical body area sensor networks.

Authors:  O Omeni; A Wong; A J Burdett; C Toumazou
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2008-12       Impact factor: 3.833

2.  Wireless technology in the evolution of patient monitoring on general hospital wards.

Authors:  R Sahandi; S Noroozi; G Roushan; V Heaslip; Y Liu
Journal:  J Med Eng Technol       Date:  2010-01

3.  A wireless medical monitoring over a heterogeneous sensor network.

Authors:  Mehmet R Yuce; Peng Choong Ng; Chin K Lee; Jamil Y Khan; Wentai Liu
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2007
  3 in total
  6 in total

1.  A novel medium access control protocol with low delay and traffic adaptivity for wireless body area networks.

Authors:  Changle Li; Binbin Hao; Kun Zhang; Yongjun Liu; Jiandong Li
Journal:  J Med Syst       Date:  2011-03-23       Impact factor: 4.460

2.  Energy Efficient Monitoring of Metered Dose Inhaler Usage.

Authors:  Aris S Lalos; John Lakoumentas; Anastasios Dimas; Konstantinos Moustakas
Journal:  J Med Syst       Date:  2016-10-29       Impact factor: 4.460

3.  An Implementation of Wireless Body Area Networks for Improving Priority Data Transmission Delay.

Authors:  Köksal Gündoğdu; Ali Çalhan
Journal:  J Med Syst       Date:  2016-01-18       Impact factor: 4.460

4.  Data-Centric Routing for Intra Wireless Body Sensor Networks.

Authors:  Javed Iqbal Bangash; Abdul Waheed Khan; Abdul Hanan Abdullah
Journal:  J Med Syst       Date:  2015-08-05       Impact factor: 4.460

5.  An Interference-Aware Traffic-Priority-Based Link Scheduling Algorithm for Interference Mitigation in Multiple Wireless Body Area Networks.

Authors:  Thien T T Le; Sangman Moh
Journal:  Sensors (Basel)       Date:  2016-12-20       Impact factor: 3.576

Review 6.  Prescription drug coverage in Canada: a review of the economic, policy and political considerations for universal pharmacare.

Authors:  Jaden Brandt; Brenna Shearer; Steven G Morgan
Journal:  J Pharm Policy Pract       Date:  2018-11-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.