Literature DB >> 20953508

Self-assembled monolayer based impedimetric platform for food borne mycotoxin detection.

Pratima Rathee Solanki1, Ajeet Kaushik, T Manaka, Manoj Kumar Pandey, M Iwamoto, Ved Varun Agrawal, Bansi Dhar Malhotra.   

Abstract

A self-assembled monolayer (SAM) of 11-amino-1-undecanethiol (AUT) has been fabricated onto a gold (Au) substrate to co-immobilize anti-ochratoxin-A antibodies (AO-IgGs) and bovine serum albumin (BSA) to detect food borne mycotoxin [i.e., ochratoxin-A (OTA)]. AUT/Au electrode, AO-IgGs/AUT/Au immunoelectrode and BSA/IgGs/AUT/Au immunoelectrode have been characterized using scanning electron microscopy (SEM) and electrochemical studies such as cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). Electrochemical studies reveal that the AUT-SAM with NH2 groups provide favorable conditions to immobilize AO-IgGs with better orientation, resulting in enhanced electron transport to obtain improved sensing characteristics. The EIS response studies of the BSA/AO-IgGs/AUT/Au immunoelectrode obtained as a function of OTA concentration reveal that the value of the charge transfer resistance (RCT) increases with increased OTA concentration. The BSA/AO-IgGs/AUT/Au immunoelectrode exhibits linearity over 0.5-6.0 ng/dl, detection limit of 0.08 ng/dl using 3σb/m criteria, response time of 30 s and sensitivity of ∼36.83 Ω/ng dl(-1) cm(-2) with a regression coefficient of 0.999. Attempts have been made to monitor the change in RCT of BSA/AO-IgGs/AUT/Au immunoelectrode on addition of coffee samples.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20953508     DOI: 10.1039/c0nr00289e

Source DB:  PubMed          Journal:  Nanoscale        ISSN: 2040-3364            Impact factor:   7.790


  4 in total

Review 1.  Improvement strategies of food supply chain through novel food processing technologies during COVID-19 pandemic.

Authors:  Bimal Chitrakar; Min Zhang; Bhesh Bhandari
Journal:  Food Control       Date:  2021-02-27       Impact factor: 5.548

2.  Ochratoxin A Detection on Antibody- Immobilized on BSA-Functionalized Gold Electrodes.

Authors:  Mihaela Badea; Laura Floroian; Patrizia Restani; Simona Codruta Aurora Cobzac; Marius Moga
Journal:  PLoS One       Date:  2016-07-28       Impact factor: 3.240

Review 3.  Mycotoxin Determination in Foods Using Advanced Sensors Based on Antibodies or Aptamers.

Authors:  Lin Xu; Zhaowei Zhang; Qi Zhang; Peiwu Li
Journal:  Toxins (Basel)       Date:  2016-08-12       Impact factor: 4.546

Review 4.  A review on impedimetric immunosensors for pathogen and biomarker detection.

Authors:  J Leva-Bueno; Sally A Peyman; P A Millner
Journal:  Med Microbiol Immunol       Date:  2020-04-03       Impact factor: 3.402

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.