Miniaturized salting-out liquid-liquid extraction of sulfonamides from different matrices.

Juanjuan Liu1, Ming Jiang, Gao Li, Li Xu, Minjie Xie.   

Abstract

Salting-out liquid-liquid extraction (LLE) uses water-miscible organic solvents as the extractants. The principle of it is based on the phase separation of water-miscible organic solvents from the aqueous solutions in the presence of high concentration of salts. As an effort to miniaturization, in the present study, a 1-mL syringe was employed as the phase separation device for salting-out LLE. Once the phase separation occurred, the upper layer could be narrowed into the needle tip by pushing the plunger; thus, the collection of the upper layer solvent was convenient. By miniaturization, the consumption of organic solvent was decreased as low as possible. Four sulfonamides were used as model analytes. The optimal salting-out parameters were as follows. 150 μL of acetonitrile was added to the 500 μL of sample solution containing 300 mg mL(-1) sodium chloride at a pH of 6.5. This procedure afforded a convenient, fast and cost-saving operation with good cleanup ability for the model analytes. It showed promising applications for different matrices. Herein, food (honey), environmental water (river water) and biological fluid (human urine) were investigated. Satisfactory results were obtained. An additional bonus of this sample preparation method is that, owing to its water-miscible nature, the extraction solvent is compatible with various analytical systems, like gas chromatography, high-performance liquid chromatography and capillary electrophoresis.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20951859     DOI: 10.1016/j.aca.2010.09.013

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Microwave-assisted solid-phase synthesis of nitrogen-doping carbon dot with good solvent compatibility and its sensing of sunitinib.

Authors:  Zhao Xu; Cong Zhang; Xu Yu; Heng Zheng; Li Xu
Journal:  Anal Bioanal Chem       Date:  2021-08-17       Impact factor: 4.142

2.  A cartridge-based device for automated analyses of solid matrices by online sample prep-capillary LC-MS/MS.

Authors:  Edvaldo Vasconcelos Soares Maciel; Fernando Mauro Lanças
Journal:  Anal Bioanal Chem       Date:  2022-02-02       Impact factor: 4.142

3.  Multiresidue Method for Quantification of Sulfonamides and Trimethoprim in Tilapia Fillet by Liquid Chromatography Coupled to Quadrupole Time-of-Flight Mass Spectrometry Using QuEChERS for Sample Preparation.

Authors:  Kátia S D Nunes; Márcia R Assalin; José H Vallim; Claudio M Jonsson; Sonia C N Queiroz; Felix G R Reyes
Journal:  J Anal Methods Chem       Date:  2018-03-01       Impact factor: 2.193

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.