Determination of cyanide in wastewaters using modified glassy carbon electrode with immobilized silver hexacyanoferrate nanoparticles on multiwall carbon nanotube.

Meissam Noroozifar1, Mozhgan Khorasani-Motlagh, Aboozar Taheri.   

Abstract

The sensitive determination of cyanide in wastewaters using modified GC electrode with silver hexacyanoferrate nanoparticles (SHFNPs) immobilized on multiwall carbon nanotube (MWCNT) was reported. The immobilization of SHFNPs on MWCNT was confirmed by transmission electron microscopy (TEM). The TEM image showed that the SHFNPs retained the spherical morphology after immobilized on MWCNT. The size of SHFNPs was examined around 27 nm. The GC/MWCNT-SHFNPs was used for the determination of cyanide in borax buffer (BB) solution (pH 8.0). Using square wave voltammetry, the current response of cyanide increases linearly while increasing its concentration from 40.0 nM to 150.0 μM and a detection limit was found to be 8.3 nM (S/N=3). The present modified electrode was also successfully used for the determination of 5.0 μM cyanide in the presence of common contaminants at levels presenting in industrial wastewaters. The practical application of the present modified electrode was demonstrated by measuring the concentration of cyanide in industrial wastewater samples. Moreover, the studied sensor exhibited high sensitivity, good reproducibility and long-term stability.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20951497     DOI: 10.1016/j.jhazmat.2010.09.026

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  3 in total

1.  Modified carbon nanotube paste electrode for voltammetric determination of carbidopa, folic Acid, and tryptophan.

Authors:  Sakineh Esfandiari Baghbamidi; Hadi Beitollahi; Hassan Karimi-Maleh; Somayeh Soltani-Nejad; Vahhab Soltani-Nejad; Sara Roodsaz
Journal:  J Anal Methods Chem       Date:  2012-05-15       Impact factor: 2.193

2.  New synthesis of poly ortho-methoxyaniline nanostructures and its application to construct modified multi-wall carbon nanotube/graphite paste electrode for simultaneous determination of uric acid and folic acid.

Authors:  Hossein Rajabi; Meissam Noroozifar
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2017-02-27       Impact factor: 7.328

Review 3.  Cyanides in the environment-analysis-problems and challenges.