Literature DB >> 20950903

Contact stresses in a patient-specific unicompartmental knee replacement.

Dawie J van den Heever1, Cornie Scheffer, Pieter Erasmus, Edwin Dillon.   

Abstract

BACKGROUND: Unicompartmental knee replacement has gained popularity in recent times, showing improved success rates. The main reasons for the failure of unicompartmental knee replacement are the wear of the polyethylene bearing, aseptic loosening and wear in the opposite compartment. The contact stresses involved are significant contributing factors to these causes of failure.
METHODS: In this study, a patient-specific unicompartmental knee replacement is proposed using a methodology based on neural network modeling of a database of healthy knee geometries. This custom implant was then compared to two conventional implant designs in terms of contact stress in a validated finite element model.
FINDINGS: The custom implant experienced lower contact stresses at the tibio-femoral joint compared to a fixed-bearing design and also displayed more uniform stress distribution at the bone-implant interface than any of the other implant designs.
INTERPRETATION: Custom unicompartmental knee replacements therefore have the potential of providing good contact stress distribution, preserve bone stock and could be more anatomically accurate.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20950903     DOI: 10.1016/j.clinbiomech.2010.09.007

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  13 in total

Review 1.  [Research progress on finite element analysis of unicompartmental knee arthroplasty in medial knee compartmental osteoarthritis].

Authors:  Huazhang Xiong; Yi Zeng; Haibo Si; Yuangang Wu; Bin Shen
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-06-15

2.  Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model.

Authors:  Y-G Koh; J Son; S-K Kwon; H-J Kim; O-R Kwon; K-T Kang
Journal:  Bone Joint Res       Date:  2017-09       Impact factor: 5.853

3.  A Fully Functional Drug-Eluting Joint Implant.

Authors:  V J Suhardi; D A Bichara; Sjj Kwok; A A Freiberg; H Rubash; H Malchau; S H Yun; O K Muratoglu; E Oral
Journal:  Nat Biomed Eng       Date:  2017-06-13       Impact factor: 25.671

4.  Patient-specific medial unicompartmental knee arthroplasty has a greater protective effect on articular cartilage in the lateral compartment: A Finite Element Analysis.

Authors:  K-T Kang; J Son; D-S Suh; S K Kwon; O-R Kwon; Y-G Koh
Journal:  Bone Joint Res       Date:  2018-01       Impact factor: 5.853

5.  Malpositioning of Prosthesis: Patient-specific Total Knee Arthroplasty Versus Standard Off-the-Shelf Total Knee Arthroplasty.

Authors:  Kyoung-Tak Kang; Juhyun Son; Oh-Ryong Kwon; Yong-Gon Koh
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2017-08-02

6.  Effect of Post-Cam Design for Normal Knee Joint Kinematic, Ligament, and Quadriceps Force in Patient-Specific Posterior-Stabilized Total Knee Arthroplasty by Using Finite Element Analysis.

Authors:  Yong-Gon Koh; Juhyun Son; Oh-Ryong Kwon; Sae Kwang Kwon; Kyoung-Tak Kang
Journal:  Biomed Res Int       Date:  2018-09-19       Impact factor: 3.411

7.  Influence of tibiofemoral congruency design on the wear of patient-specific unicompartmental knee arthroplasty using finite element analysis.

Authors:  Y-G Koh; K-M Park; H-Y Lee; K-T Kang
Journal:  Bone Joint Res       Date:  2019-04-02       Impact factor: 5.853

Review 8.  Recent advances in computational mechanics of the human knee joint.

Authors:  M Kazemi; Y Dabiri; L P Li
Journal:  Comput Math Methods Med       Date:  2013-02-19       Impact factor: 2.238

9.  Biomechanical assessment of a patient-specific knee implant design using finite element method.

Authors:  Qiguo Rong; Jianfeng Bai; Yongling Huang; Jianhao Lin
Journal:  Biomed Res Int       Date:  2014-06-30       Impact factor: 3.411

10.  Effects of Lower Limb Alignment and Tibial Component Inclination on the Biomechanics of Lateral Compartment in Unicompartmental Knee Arthroplasty.

Authors:  Peng-Fei Wen; Wan-Shou Guo; Fu-Qiang Gao; Qi-Dong Zhang; Ju-An Yue; Li-Ming Cheng; Guang-Duo Zhu
Journal:  Chin Med J (Engl)       Date:  2017-11-05       Impact factor: 2.628

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.