Literature DB >> 20949570

Role of intraoperative microvascular Doppler in the microsurgical management of intracranial aneurysms.

Hua Cui1, Yong Wang, Yuhua Yin, Jieqing Wan, Zhimin Fei, Weizhen Gao, Jiyao Jiang.   

Abstract

BACKGROUND: The outcome of surgical treatment of intracranial aneurysms may be influenced by incomplete exclusion of the aneurysm or stenosis of the parent vessels. The goal of this study was to evaluate the usefulness and reliability of intraoperative microvascular Doppler (IMD) in guiding optimal clip placement in aneurysm surgery.
METHODS: We conducted a retrospective analysis of 79 patients, with a total of 85 intracranial aneurysms, operated between January 2004 and April 2009, who were evaluated with IMD using a 20-MHz probe before and after clip application. IMD was used to examine the aneurysmal sac and adjacent vessels.
RESULTS: The findings of IMD helped in adjusting the clip placement. In 9 (10.6%) of the 85 aneurysms, IMD revealed a persistent blood flow through the aneurysmal sac after clip application and the clip was repositioned. IMD showed relevant stenosis of adjacent vessels induced by the clip positioning in 10 of 79 (12.7%) cases. In six cases (7.6%), a blood flow reduction in the artery feeding the aneurysm was evident after clipping; in the other four cases (5.1%), the clip produced a severe blood flow reduction in other adjacent vessels. In addition, in two of these cases, an initial stenosis induced by clip positioning that had escaped detection by visual inspection through the operating microscope was identified by IMD. There were no complications related to the use of IMD.
CONCLUSIONS: IMD is a safe, feasible, and very reliable technique and should be used routinely in intracranial aneurysm surgery.
Copyright © 2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20949570     DOI: 10.1002/jcu.20751

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  5 in total

1.  The role of intraoperative micro-Doppler ultrasound in verifying proper clip placement in intracranial aneurysm surgery.

Authors:  Ioannis Siasios; Eftychia Z Kapsalaki; Kostas N Fountas
Journal:  Neuroradiology       Date:  2012-03-14       Impact factor: 2.804

2.  Intraoperative motor-evoked potential monitoring during coil embolization for anterior choroidal artery aneurysms.

Authors:  Akira Ito; Kenichi Sato; Kuniyasu Niizuma; Hidenori Endo; Yasushi Matsumoto; Teiji Tominaga
Journal:  Neuroradiology       Date:  2021-11-17       Impact factor: 2.804

Review 3.  The Clinical Importance of Perforator Preservation in Intracranial Aneurysm Surgery: An Overview with a Review of the Literature.

Authors:  Sung-Pil Joo; Tae-Sun Kim
Journal:  Chonnam Med J       Date:  2017-01-25

4.  Intraoperative Combined Use of Somatosensory Evoked Potential, Microvascular Doppler Sonography, and Indocyanine Green Angiography in Clipping of Intracranial Aneurysm.

Authors:  Zhili Li; Guanni Zhang; Guangfu Huang; Zhengyu Wang; Haibin Tan; Jinping Liu; Aiguo Li
Journal:  Med Sci Monit       Date:  2016-02-04

5.  A pilot study on assessing the role of intra-operative Flow 800 vascular map model in predicting onset of vasospasm following micro vascular clipping of ruptured intracranial aneurysms.

Authors:  Sunil Munakomi; Deepak Poudel
Journal:  F1000Res       Date:  2018-08-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.