Literature DB >> 20949253

[Automated breast volume scanner (ABVS) : a new approach for breast imaging].

N K Wöhrle1, K Hellerhoff, M Notohamiprodjo, M F Reiser, D-A Clevert.   

Abstract

The automated breast ultrasound technique has been known for a long time but did not play an important role in diagnostics due to its inferior sensitivity for small solid lesions with low frequency transducers and its uncomfortable examination technique with the patients in a supine position and the breast immersed in water. The automated breast volume scanner (AVBS) is a high-end ultrasound scanner which employs frequencies of 5-14 MHz and consists of a flexible arm with the transducer at the end, a touchscreen and a 3D workstation. The scan is performed with the patient in the prone position. Depending on the breast size, various presettings are available from which the examiner may select the most appropriate. AVBS has various major advantages, such as being independent from the experience of the operator as well as supplying consistent and reproducible results. Additionally, for the first time it became possible to obtain coronal images of the complete breast, which greatly assists the planning of surgical interventions. In this article the ABVS technique will be described and results will be illustrated by means of clinical examples.

Entities:  

Mesh:

Year:  2010        PMID: 20949253     DOI: 10.1007/s00117-010-2068-8

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  18 in total

1.  [Quality control in breast sonography].

Authors:  H Madjar; A Mundinger; F Degenhardt; V Duda; B J Hackelöer; R Osmers
Journal:  Ultraschall Med       Date:  2003-06       Impact factor: 6.548

Review 2.  [The suitability of high-resolution ultrasound for the detection of DCIS].

Authors:  H Hille; M Vetter; B J Hackelöer
Journal:  Ultraschall Med       Date:  2007-06       Impact factor: 6.548

3.  Sonographic criteria for the confirmation of implant rotation and the development of an implant-capsule-interaction ("interface") in anatomically formed textured breast implants with texturised Biocell-surface.

Authors:  M Hahn; R P Kuner; P Scheler; K Freidel; G Hoffmann; H Madjar; D Wallwiener; U Krainick-Strobel
Journal:  Ultraschall Med       Date:  2007-07-03       Impact factor: 6.548

4.  Analysis of 107 breast lesions with automated 3D ultrasound and comparison with mammography and manual ultrasound.

Authors:  D Kotsianos-Hermle; K M Hiltawsky; S Wirth; T Fischer; K Friese; M Reiser
Journal:  Eur J Radiol       Date:  2008-05-12       Impact factor: 3.528

5.  First clinical use of a standardized three-dimensional ultrasound for breast imaging.

Authors:  D Kotsianos-Hermle; S Wirth; T Fischer; K M Hiltawsky; M Reiser
Journal:  Eur J Radiol       Date:  2008-05-14       Impact factor: 3.528

6.  Ultrasonography of breast lesions detected in mammography screening.

Authors:  M Pamilo; M Soiva; I Anttinen; M Roiha; I Suramo
Journal:  Acta Radiol       Date:  1991-05       Impact factor: 1.990

7.  Occult cancer in women with dense breasts: detection with screening US--diagnostic yield and tumor characteristics.

Authors:  T M Kolb; J Lichy; J H Newhouse
Journal:  Radiology       Date:  1998-04       Impact factor: 11.105

8.  Optimal scanning technique to cover the whole breast using an automated breast volume scanner.

Authors:  Mitsuhiro Tozaki; Sachiko Isobe; Miki Yamaguchi; Yukari Ogawa; Masami Kohara; Chanwoong Joo; Eisuke Fukuma
Journal:  Jpn J Radiol       Date:  2010-05-29       Impact factor: 2.374

9.  The role of mean diffusivity (MD) as a predictive index of the response to chemotherapy in locally advanced breast cancer: a preliminary study.

Authors:  Chiara Iacconi; Marco Giannelli; Carolina Marini; Anna Cilotti; Monica Moretti; Paolo Viacava; Eugenia Picano; Andrea Michelotti; Davide Caramella
Journal:  Eur Radiol       Date:  2009-09-17       Impact factor: 5.315

10.  [Comparison of mammography and automated sonography in 700 patients].

Authors:  M Kessler; W Igl; B Krauss; R Bassermann; D H Bohmert; W Eiermann; K J Lohe; J Lissner
Journal:  Rofo       Date:  1983-03
View more
  4 in total

1.  Evaluation of a Novel Semi-Automated Ultrasound System for the Detection of Synovitis: A Prospective Study involving 45 Patients with Rheumatoid Arthritis.

Authors:  M Witt; J Frielinghausen; R Mueller; F Mueller; F Proft; H Schulze-Koops; M Grunke; D-A Clevert
Journal:  Ultrasound Int Open       Date:  2016-09-14

2.  The clinical utility of automated breast volume scanner: a pilot study of 139 cases.

Authors:  Young Wook Kim; Seon Kwang Kim; Hyun Jo Youn; Eun Jung Choi; Sung Hoo Jung
Journal:  J Breast Cancer       Date:  2013-09-30       Impact factor: 3.588

3.  Evaluation of automated breast volume scanner for breast conservation surgery in ductal carcinoma in situ.

Authors:  Anqian Huang; Luoxi Zhu; Yanjuan Tan; Jian Liu; Jingjing Xiang; Qingqing Zhu; Lingyun Bao
Journal:  Oncol Lett       Date:  2016-07-29       Impact factor: 2.967

4.  The Value of an Automated Ultrasound System in the Detection of Synovitis.

Authors:  Ruediger Mueller; Mathias Grunke; Jörg Wendler; Florian Schuch; Karina Hofmann-Preiss; Ina Boettger; Rüdiger Jakobs; Hendrik Schulze-Koops; Johannes von Kempis
Journal:  Ultrasound Int Open       Date:  2018-07-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.