Literature DB >> 20946281

A highly accurate and consistent microfluidic viscometer for continuous blood viscosity measurement.

Yang Jun Kang1, Sang Youl Yoon, Kyeong-Hwan Lee, Sung Yang.   

Abstract

A high-precision microfluidic viscometer with a microfluidic channel array composed of 100 indicating channels is demonstrated in this study. The relative viscosity of the sample fluid could be measured by simply counting the number of the indicating channels occupied by the sample and the reference fluids. Using lumped parameter modeling, an analytical solution of the relative viscosity is derived. In order to evaluate the performance of the developed microfluidic viscometer, the viscosity values obtained by the microfluidic viscometer are compared with the ones obtained by a conventional viscometer. In Newtonian fluid (sodium dodecyl sulfate [SDS] solution) tests, the normalized differences in the viscosities measured by two methods are less than 2.5%. In non-Newtonian fluid (whole blood, 45% hematocrit) tests at various shear rates, the viscosities measured by two methods are evaluated by a regression analysis via power law (). The k values for both the microfluidic viscometer and the conventional viscometer are 12.953 and 13.175, respectively; the n values are 0.797 and 0.807, respectively. The normalized differences in two parameters measured by two methods are less than 2%. Thus, it could be concluded that the microfluidic viscometer developed in this study is capable of measuring viscosity of both Newtonian fluid (SDS solution) and non-Newtonian fluid (whole blood) with a relatively high accuracy in a continuous and near real-time fashion. Furthermore, the viscometer could be potentially employed in cardiopulmonary bypass procedures by continuously monitoring viscosity changes due to blood damages and hemodilution.
© 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20946281     DOI: 10.1111/j.1525-1594.2010.01078.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  12 in total

1.  Gravity-induced swirl of nanoparticles in microfluidics.

Authors:  Chao Zhao; Alparslan Oztekin; Xuanhong Cheng
Journal:  J Nanopart Res       Date:  2013-04-01       Impact factor: 2.253

Review 2.  Microfluidic viscometers for shear rheology of complex fluids and biofluids.

Authors:  Siddhartha Gupta; William S Wang; Siva A Vanapalli
Journal:  Biomicrofluidics       Date:  2016-07-05       Impact factor: 2.800

3.  Periodic and simultaneous quantification of blood viscosity and red blood cell aggregation using a microfluidic platform under in-vitro closed-loop circulation.

Authors:  Yang Jun Kang
Journal:  Biomicrofluidics       Date:  2018-04-09       Impact factor: 2.800

4.  The centrifugal viscometer.

Authors:  Chih-Hsin Shih; Chia-Chin Chang; Chung-Yi Liu; Ho-Chin Wu
Journal:  Biomicrofluidics       Date:  2021-09-01       Impact factor: 3.258

5.  Microfluidic-Based Measurement Method of Red Blood Cell Aggregation under Hematocrit Variations.

Authors:  Yang Jun Kang
Journal:  Sensors (Basel)       Date:  2017-09-06       Impact factor: 3.576

6.  Micro-Viscometer for Measuring Shear-Varying Blood Viscosity over a Wide-Ranging Shear Rate.

Authors:  Byung Jun Kim; Seung Yeob Lee; Solkeun Jee; Arslan Atajanov; Sung Yang
Journal:  Sensors (Basel)       Date:  2017-06-20       Impact factor: 3.576

7.  Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood Flows.

Authors:  Yang Jun Kang
Journal:  Micromachines (Basel)       Date:  2019-08-30       Impact factor: 2.891

8.  Microfluidics Approach to the Mechanical Properties of Red Blood Cell Membrane and Their Effect on Blood Rheology.

Authors:  Claudia Trejo-Soto; Guillermo R Lázaro; Ignacio Pagonabarraga; Aurora Hernández-Machado
Journal:  Membranes (Basel)       Date:  2022-02-13

9.  Microrheometer for Biofluidic Analysis: Electronic Detection of the Fluid-Front Advancement.

Authors:  Lourdes Méndez-Mora; Maria Cabello-Fusarés; Josep Ferré-Torres; Carla Riera-Llobet; Samantha Lopez; Claudia Trejo-Soto; Tomas Alarcón; Aurora Hernandez-Machado
Journal:  Micromachines (Basel)       Date:  2021-06-20       Impact factor: 2.891

10.  Whole blood viscosity and red blood cell adhesion: Potential biomarkers for targeted and curative therapies in sickle cell disease.

Authors:  Erdem Kucukal; Yuncheng Man; Ailis Hill; Shichen Liu; Allison Bode; Ran An; Jaikrishnan Kadambi; Jane A Little; Umut A Gurkan
Journal:  Am J Hematol       Date:  2020-08-10       Impact factor: 10.047

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.