Literature DB >> 20945077

Authentication and self-correction in sequential MRI slices.

Vassilis Fotopoulos1, Maria L Stavrinou, Athanassios N Skodras.   

Abstract

One of the new challenges of Information Technology in the medical world is the protection and authentication of a variety of digital medical files, datasets, and images. In this work, the ability of magnetic resonance imaging (MRI) slice sequences to hide digital data is investigated and more specifically the case that the hidden data are the regions of interest (ROI) of the MRI slices. The regions of non-interest (RONI) are used as cover. The hiding capacity of the whole sequence is taken into account. Any ROI-targeted tampering attempt can be detected, and the original image can be self-restored (under certain conditions) by extracting the ROI from the RONI.

Mesh:

Year:  2011        PMID: 20945077      PMCID: PMC3180543          DOI: 10.1007/s10278-010-9340-3

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  5 in total

1.  Secure and efficient health data management through multiple watermarking on medical images.

Authors:  A Giakoumaki; S Pavlopoulos; D Koutsouris
Journal:  Med Biol Eng Comput       Date:  2006-07-19       Impact factor: 2.602

Review 2.  A review of image watermarking applications in healthcare.

Authors:  G Coatrieux; L Lecornu; B Sankur; Ch Roux
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

3.  A region-based lossless watermarking scheme for enhancing security of medical data.

Authors:  Xiaotao Guo; Tian-Ge Zhuang
Journal:  J Digit Imaging       Date:  2009-03       Impact factor: 4.056

4.  Mixed reversible and RONI watermarking for medical image reliability protection.

Authors:  G Coatrieux; J Montagner; H Huang; Ch Roux
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2007

5.  Cerebellar activity switches hemispheres with cerebral recovery in aphasia.

Authors:  Lisa Tabor Connor; Tiffany DeShazo Braby; Abraham Z Snyder; Christopher Lewis; Valeria Blasi; Maurizio Corbetta
Journal:  Neuropsychologia       Date:  2005-07-12       Impact factor: 3.139

  5 in total
  2 in total

1.  PDE based scheme for multi-modal medical image watermarking.

Authors:  N Aherrahrou; H Tairi
Journal:  Biomed Eng Online       Date:  2015-11-25       Impact factor: 2.819

2.  An Encryption Algorithm for Region of Interest in Medical DICOM Based on One-Dimensional eλ-cos-cot Map.

Authors:  Xin Meng; Jinqing Li; Xiaoqiang Di; Yaohui Sheng; Donghua Jiang
Journal:  Entropy (Basel)       Date:  2022-06-29       Impact factor: 2.738

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.