Literature DB >> 20944935

Ability of corneal biomechanical metrics and anterior segment data in the differentiation of keratoconus and healthy corneas.

Bruno Machado Fontes1, Renato Ambrósio Junior, Daniela Jardim, Guillermo Coca Velarde, Walton Nosé.   

Abstract

PURPOSE: To evaluate the sensitivity, specificity, and test accuracy of corneal biomechanical metrics and anterior segment data in differentiating keratoconus from healthy corneas.
METHODS: Comparative case series. Patients with and without keratoconus (gender and age-matched) were submitted for complete eye examinations including corneal hysteresis (CH) and corneal resistance factor (CRF) as measured by the Ocular Response Analyzer and anterior segment data as gathered through Pentacam assessments. The anterior segment data measurement included average central keratometric readings (K-Ave), corneal astigmatism (CA), central corneal thickness (CCT), anterior chamber depth (AC depth) and corneal volume (CV). All parameters were assessed, compared and analyzed. A receiver operating characteristic (ROC) curve was used to identify the best cutoff point by which to maximize the sensitivity and specificity of discriminating keratoconus from normal corneas for each data category.
RESULTS: Seventy seven eyes from forty three patients (24 male, 19 female) with keratoconus and eighty six eyes from forty three (24 male, 19 female) healthy controls were enrolled. ROC curve analysis showed poor overall predictive accuracy for all studied parameters in differentiating keratoconus from normal corneas. The highest sensitivity (79.2%) was obtained for both AC depth and CH (cutoff points 3.22 mm and 9.39 mmHg respectively). The best specificity (89.5%) and test accuracy (80.34%) were obtained for CA (cutoff point of 2.2 D).
CONCLUSION: When considered together, studied parameters showed statistical differences between groups. However, when considered independently they presented low sensitivity, specificity and test accuracy in differentiating keratoconus from healthy corneas.

Entities:  

Mesh:

Year:  2010        PMID: 20944935     DOI: 10.1590/s0004-27492010000400006

Source DB:  PubMed          Journal:  Arq Bras Oftalmol        ISSN: 0004-2749            Impact factor:   0.872


  13 in total

1.  Clinical utility of ocular residual astigmatism and topographic disparity vector indexes in subclinical and clinical keratoconus.

Authors:  David P Piñero; Rafael J Pérez-Cambrodí; Roberto Soto-Negro; Pedro Ruiz-Fortes; Alberto Artola
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-09-07       Impact factor: 3.117

2.  [New aspects on biomechanics of the cornea in keratoconus].

Authors:  Z Gatzioufas; B Seitz
Journal:  Ophthalmologe       Date:  2013-09       Impact factor: 1.059

3.  Anterior chamber depth in normal subjects by rotating scheimpflug imaging.

Authors:  Matthew T Feng; Michael W Belin; Renato Ambrósio; Satinder P S Grewal; Wang Yan; Mohamed S Shaheen; Charles McGhee; Naoyuki Maeda; Tobias H Neuhann; H Burkhard Dick; Saleh A Alageel; Andreas Steinmueller
Journal:  Saudi J Ophthalmol       Date:  2011-04-30

4.  Short-term effects of overnight orthokeratology on corneal epithelial permeability and biomechanical properties.

Authors:  Thao N Yeh; Harry M Green; Yixiu Zhou; Julie Pitts; Britney Kitamata-Wong; Sophia Lee; Shiyin L Wang; Meng C Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-06-06       Impact factor: 4.799

5.  Detection of the early keratoconus based on corneal biomechanical properties in the refractive surgery candidates.

Authors:  Zofia Pniakowska; Piotr Jurowski
Journal:  Indian J Ophthalmol       Date:  2016-02       Impact factor: 1.848

6.  Corneal Biomechanics in Ectatic Diseases: Refractive Surgery Implications.

Authors:  Renato Ambrósio; Fernando Faria Correia; Bernardo Lopes; Marcella Q Salomão; Allan Luz; Daniel G Dawson; Ahmed Elsheikh; Riccardo Vinciguerra; Paolo Vinciguerra; Cynthia J Roberts
Journal:  Open Ophthalmol J       Date:  2017-07-31

7.  Keratoconus diagnosis using Corvis ST measured biomechanical parameters.

Authors:  Roghiyeh Elham; Ebrahim Jafarzadehpur; Hassan Hashemi; Kazem Amanzadeh; Fereshteh Shokrollahzadeh; Abbasali Yekta; Mehdi Khabazkhoob
Journal:  J Curr Ophthalmol       Date:  2017-05-22

Review 8.  Advances in Biomechanical Parameters for Screening of Refractive Surgery Candidates: A Review of the Literature, Part III.

Authors:  Majid Moshirfar; Mahsaw N Motlagh; Michael S Murri; Hamed Momeni-Moghaddam; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2019

Review 9.  Corneal biomechanical properties in different ocular conditions and new measurement techniques.

Authors:  Nery Garcia-Porta; Paulo Fernandes; Antonio Queiros; Jose Salgado-Borges; Manuel Parafita-Mato; Jose Manuel González-Méijome
Journal:  ISRN Ophthalmol       Date:  2014-03-04

10.  Measurement of anterior segment parameters in Saudi adults with myopia.

Authors:  Lujain S Alrajhi; Kholoud A Bokhary; Ahmed A Al-Saleh
Journal:  Saudi J Ophthalmol       Date:  2018-05-14
View more