Literature DB >> 20942851

The prothrombin time/international normalized ratio (PT/INR) Line: derivation of local INR with commercial thromboplastins and coagulometers--two independent studies.

L Poller1, S Ibrahim, M Keown, A Pattison, J Jespersen.   

Abstract

BACKGROUND: The WHO scheme for prothrombin time (PT) standardization has been limited in application, because of its difficulties in implementation, particularly the need for mandatory manual PT testing and for local provision of thromboplastin international reference preparations (IRP).
METHODS: The value of a new simpler procedure to derive international normalized ratio (INR), the PT/INR Line, based on only five European Concerted Action on Anticoagulation (ECAA) calibrant plasmas certified by experienced centres has been assessed in two independent exercises using a range of commercial thromboplastins and coagulometers. INRs were compared with manual certified values with thromboplastin IRP from expert centres and in the second study also with INRs from local ISI calibrations.
RESULTS: In the first study with the PT/INR Line, 8.7% deviation from certified INRs was reduced to 1.1% with human reagents, and from 7.0% to 2.6% with rabbit reagents. In the second study, deviation was reduced from 11.2% to 0.4% with human reagents by both local ISI calibration and the PT/INR Line. With rabbit reagents, 10.4% deviation was reduced to 1.1% with both procedures; 4.9% deviation was reduced to 0.5% with bovine/combined reagents with local ISI calibrations and to 2.9% with the PT/INR Line. Mean INR dispersion was reduced with all thromboplastins and automated systems using the PT/INR Line.
CONCLUSIONS: The procedure using the PT/INR Line provides reliable INR derivation without the need for WHO ISI calibration across the range of locally used commercial thromboplastins and automated PT systems included in two independent international studies.
© 2010 International Society on Thrombosis and Haemostasis.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 20942851     DOI: 10.1111/j.1538-7836.2010.04109.x

Source DB:  PubMed          Journal:  J Thromb Haemost        ISSN: 1538-7836            Impact factor:   5.824


  6 in total

1.  The Role of Ischemia Modified Albumin as a Biomarker in Patients with Chronic Liver Disease.

Authors:  Prashanth Ashok Kumar; Kavitha Subramanian
Journal:  J Clin Diagn Res       Date:  2016-03-01

Review 2.  Measurement of non-VKA oral anticoagulants versus classic ones: the appropriate use of hemostasis assays.

Authors:  Jonathan Douxfils; Anne Tamigniau; Bernard Chatelain; Catherine Goffinet; Jean-Michel Dogné; François Mullier
Journal:  Thromb J       Date:  2014-11-04

3.  Data documenting the performance of the PT/INR line correction method for reconciling INR discrepancies between central laboratory coagulation analyzers using different thromboplastins during the evaluation of a portable Coagulometer.

Authors:  Wendy S Baker; Kathleen J Albright; Heidi Spratt; Megan Berman; Peggy A Mann; Jaime Unabia; John R Petersen
Journal:  Data Brief       Date:  2017-11-07

4.  Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

Authors:  Ana Bronić; Desiree Coen Herak; Sandra Margetić; Marija Milić
Journal:  Biochem Med (Zagreb)       Date:  2017-02-15       Impact factor: 2.313

5.  Development of an Optical Method for the Evaluation of Whole Blood Coagulation.

Authors:  Marinos Louka; Efstathios Kaliviotis
Journal:  Biosensors (Basel)       Date:  2021-04-09

Review 6.  Updates on Anticoagulation and Laboratory Tools for Therapy Monitoring of Heparin, Vitamin K Antagonists and Direct Oral Anticoagulants.

Authors:  Osamu Kumano; Kohei Akatsuchi; Jean Amiral
Journal:  Biomedicines       Date:  2021-03-07
  6 in total