Literature DB >> 20940092

Efficiency of the new sub-2 μm core-shell (Kinetex™) column in practice, applied for small and large molecule separation.

Szabolcs Fekete1, Katalin Ganzler, Jeno Fekete.   

Abstract

At present sub-2 μm packed columns are very popular to accomplish rapid and efficient separations. Applying particles with shortened diffusion path to improve the efficiency of separation performs higher efficiency than it is possible with the totally porous particles having the same size. The advantages of sub-2 μm particles and shell particles are combined in the new Kinetex 1.7 μm particles. In this study a systematical evaluation of the efficiency and achievable analysis time obtained with 5 cm long narrow bore column packed with sub-2 μm core-shell particles (1.25 μm core diameter and 0.23 μm porous silica layer), and other type very efficient columns is presented. The efficiency of separation was investigated also for small pharmaceutical and large molecules (proteins). Van Deemter, Knox and kinetic plots are calculated. The results obtained with low molecular weight polar neutral analytes (272 g/mol, 875 g/mol), with a polypeptide (4.1 kDa) and with different sized proteins (18.8 kDa, 38.9 kDa and 66.3 kDa) are presented in this study. Moreover, particle size distribution, and average pore size (low-temperature nitrogen adsorption, LTNA) of the new very fine core-shell particles were investigated. According to this study, increased flow rates can be applied on sub-2 μm core-shell columns to accomplish very fast separations without significant loss in efficiency. The new sub-2 μm shell particles offer very high efficiency both for small and large molecule separation.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20940092     DOI: 10.1016/j.jpba.2010.09.021

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  6 in total

1.  Development of an online SPE-LC-MS-based assay using endogenous substrate for investigation of soluble epoxide hydrolase (sEH) inhibitors.

Authors:  Nils Helge Schebb; Marion Huby; Christophe Morisseau; Sung Hee Hwang; Bruce D Hammock
Journal:  Anal Bioanal Chem       Date:  2011-04-09       Impact factor: 4.142

2.  A high-resolution measurement of nucleotide sugars by using ion-pair reverse chromatography and tandem columns.

Authors:  Sha Sha; Garry Handelman; Cyrus Agarabi; Seongkyu Yoon
Journal:  Anal Bioanal Chem       Date:  2020-04-16       Impact factor: 4.142

3.  Validation and application of sub-2 μm core-shell UHPLC-UV-ESI-Orbitrap MS for identification and quantification of β-carotene and selected cleavage products with preceding solid-phase extraction.

Authors:  G Martano; E Bojaxhi; I C Forstenlehner; C G Huber; N Bresgen; P M Eckl; H Stutz
Journal:  Anal Bioanal Chem       Date:  2014-03-21       Impact factor: 4.142

4.  A method for the simultaneous determination of chlorogenic acid and sesquiterpene lactone content in industrial chicory root foodstuffs.

Authors:  Honorine Willeman; Philippe Hance; Anne Fertin; Najia Voedts; Nathalie Duhal; Jean-François Goossens; Jean-Louis Hilbert
Journal:  ScientificWorldJournal       Date:  2014-12-04

5.  Reversed-phase fused-core HPLC modeling of peptides.

Authors:  Matthias D'Hondt; Bert Gevaert; Sofie Stalmans; Sylvia Van Dorpe; Evelien Wynendaele; Kathelijne Peremans; Christian Burvenich; Bart De Spiegeleer
Journal:  J Pharm Anal       Date:  2012-11-30

6.  A Fully Automated Online SPE-LC-MS/MS Method for the Determination of 10 Pharmaceuticals in Wastewater Samples.

Authors:  Masho Hilawie Belay; Ulrich Precht; Peter Mortensen; Emilio Marengo; Elisa Robotti
Journal:  Toxics       Date:  2022-02-23
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.