Use of abdominal chimney grafts is feasible and safe: short-term results.

Konstantinos P Donas1, Giovanni Torsello, Martin Austermann, Arne Schwindt, Nicola Troisi, Georgios A Pitoulias.   

Abstract

PURPOSE: To present our initial experience with the use of chimney grafts in endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs) with challenging anatomy.
METHODS: Among 390 EVAR cases performed at our institution between November 2008 and February 2010, 15 patients (all men; mean age 81.8 years) underwent EVAR with synchronous placement of chimney grafts. The chimney technique involved placing covered stents parallel to the main aortic stent-graft to preserve or rescue flow to aortic branch vessels while extending the proximal fixation zone. All patients presented with pararenal aortic aneurysms with short necks (between 0 and 10 mm long) that required either suprarenal clamping to tailor a proximal anastomosis in open repair or suprarenal fixation to anchor an endoprosthesis. Chimney grafts were implanted into 10 left renal and 5 right renal arteries.
RESULTS: The immediate technical success was 100%. One early type II endoleak due to retrograde flow from the inferior mesenteric artery was detected and is under surveillance. Mean follow-up was 6.8 months (range 1-13). One chimney graft occluded 45 days postoperatively; the patient underwent open thrombectomy of the left renal artery and iliorenal bypass. The creatinine value at discharge was 1.6 mg/dL, and resting renal scintigraphy showed 36% perfusion for the left kidney and 64% for the right kidney. During follow-up, no patient required hemodialysis; no aneurysm-related deaths were noted.
CONCLUSION: This limited experience demonstrates that the use of abdominal chimney grafts is feasible and safe. Long-term results in larger patient cohorts are needed evaluate the utility of this alternative endovascular technique.

Entities:  

Mesh:

Year:  2010        PMID: 20939713     DOI: 10.1583/10-3083.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  5 in total

1.  Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

Authors:  Edgar Luis Galiñanes; Eduardo A Hernandez-Vila; Zvonimir Krajcer
Journal:  Tex Heart Inst J       Date:  2015-02-01

Review 2.  Radiology of advanced EVAR techniques in complex abdominal aortic aneurysms.

Authors:  Uei Pua; Kongteng Tan
Journal:  Eur Radiol       Date:  2011-09-17       Impact factor: 5.315

3.  Early experience with the endowedge technique and snorkel technique for endovascular aneurysm repair with challenging neck anatomy.

Authors:  Kimihiro Igari; Toshifumi Kudo; Hidetoshi Uchiyama; Takahiro Toyofuku; Yoshinori Inoue
Journal:  Ann Vasc Dis       Date:  2014-02-28

Review 4.  Advanced Endovascular Approaches in the Management of Challenging Proximal Aortic Neck Anatomy: Traditional Endografts and the Snorkel Technique.

Authors:  Jon G Quatromoni; Ksenia Orlova; Paul J Foley
Journal:  Semin Intervent Radiol       Date:  2015-09       Impact factor: 1.513

5.  When the chimney is blocked: malignant renovascular hypertension after endovascular repair of abdominal aortic aneurysm.

Authors:  Amir Gal-Oz; Yehuda G Wolf; Galia Rosen; Haggai Sharon; Idit F Schwartz; Gil Chernin
Journal:  BMC Nephrol       Date:  2013-03-26       Impact factor: 2.388

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.