Split-acquisition real-time CINE phase-contrast MR flow measurements.

Jennifer A Steeden1, David Atkinson, Andrew M Taylor, Vivek Muthurangu.   

Abstract

The temporal and spatial resolution of real-time phase-contrast magnetic resonance (PCMR) is restricted by the need to acquire two interleaved phase images. In this article, we propose a split-acquisition real-time CINE PCMR technique, where the acquisition of flow-encoded and flow-compensated data is divided into separate blocks. By comparing magnitude images, automatic matching of data in cardio-respiratory space allows subtraction of background phase offsets. Thus, the data is acquired in real-time but with phase correction originating from a different heart beat. This effectively doubles the frame rate, allowing either higher temporal or spatial resolution. Two split-acquisition sequences were tested: one with high-temporal resolution and one with high-spatial resolution. Both sequences showed excellent agreement in stroke volumes in 20 adults when validated against cardiac-gated PCMR and interleaved real-time PCMR (cardiac gated: 95.2 ± 20.0 mL, interleaved real-time: 96.2 ± 20.7 mL, high-temporal resolution: 95.6 ± 20.1 mL, high-spatial resolution: 95.5 ± 20.4 mL). In six children, the high-spatial resolution sequence provided more accurate flow measurements than interleaved real-time PCMR, when compared with cardiac-gated PCMR (cardiac gated: 20.6 ± 7.6 mL, interleaved real-time: 24.3 ± 9.2 mL, high-spatial resolution: 20.8 ± 7.8 mL), due to the increased spatial resolution. The matching technique is shown to be accurate (truth: 94.6 ± 21.8, split-acquisition: 95.0 ± 21.9 mL) and quantitative image quality (signal-to-noise ratio, velocity-to-noise ratio and edge sharpness) is acceptable.
© 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 20939086     DOI: 10.1002/mrm.22615

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

1.  Longitudinal myocardial peak velocities using high temporal resolution phase-contrast and simple averaging are comparable to tissue Doppler echocardiography.

Authors:  Christophe Meyer; Laurent Bonnemains; François Marçon; Pierre-Yves Marie; Jacques Felblinger; Pierre-André Vuissoz
Journal:  MAGMA       Date:  2013-09-08       Impact factor: 2.310

2.  Real-time phase contrast magnetic resonance imaging for assessment of haemodynamics: from phantom to patients.

Authors:  Julius Traber; Lennart Wurche; Matthias A Dieringer; Wolfgang Utz; Florian von Knobelsdorff-Brenkenhoff; Andreas Greiser; Ning Jin; Jeanette Schulz-Menger
Journal:  Eur Radiol       Date:  2015-07-19       Impact factor: 5.315

3.  Rapid flow assessment of congenital heart disease with high-spatiotemporal-resolution gated spiral phase-contrast MR imaging.

Authors:  Jennifer A Steeden; David Atkinson; Michael S Hansen; Andrew M Taylor; Vivek Muthurangu
Journal:  Radiology       Date:  2011-03-17       Impact factor: 11.105

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.