Influence of the loading frequency on the wear rate of a polyethylene-on-metal lumbar intervertebral disc replacement.

Annette Kettler1, Michael Bushelow, Hans-Joachim Wilke.   

Abstract

Pre-clinical wear testing of intervertebral disc prostheses is commonly carried out according to ISO 18192-1. Ten million multiaxial loading cycles are applied at a frequency of 1 Hz. At this frequency, testing takes about 4 months. Testing at higher frequencies would therefore be desirable. ISO 18192-1 also offers testing at 2 Hz; however, it says the impact on the implant material behaviour as well as on the accuracy of the test machine shall be investigated by the user. Since such data are not available so far, the aim of this study was to carry out comparative wear tests at 1 and 2 Hz. Seven Prodisc-L lumbar disc prostheses were tested. After a pre-soak period, the implants were placed in specimen cups filled with calf serum, mounted to a Spine Wear Simulator and loaded according to ISO 18192-1. Testing was carried out at a temperature of 37 ± 2 °C. Four million loading cycles were applied at 1 Hz and eight million at 2 Hz in an alternating sequence. Each time after 12 days of testing the implants were removed to measure the weight and the height of the polyethylene cores. Then, the test serum was exchanged and the implants were remounted to the testing machine. The mean wear rate was 5.6 ± 2.3 mg per million cycles at 1 Hz and 7.7 ± 1.6 mg per million cycles at 2 Hz during the first six million loading cycles (p < 0.05) and 2.0 ± 0.6 and 4.1 ± 0.7 mg per million cycles during the second six million cycles (p < 0.05). Similarly, the mean heightloss was also smaller at 1 Hz than at 2 Hz (p < 0.05) with -0.02 ± 0.02 mm versus -0.04 ± 0.02 mm per million cycles during the first half of testing and -0.01 ± 0.01 versus -0.02 ± 0.01 mm per million cycles during the second half. The accuracy of the test machine was within the limits described by ISO 18192-1 at both frequencies. The results showed that the wear rate was higher at the beginning than at the end of testing. Also, the results indicated that testing at 2 Hz increases the wear rate compared with 1 Hz in case of a polyethylene-on-metal implant design. In the absence of retrieval studies it is difficult to decide which rate results in a more physiological wear pattern. However, a loading frequency of 1 Hz is probably closer to physiology than 2 Hz since the loading amplitudes prescribed by ISO 18192-1 are high. They rather represent movements like tying shoes or standing up from a chair than walking or sitting. The authors therefore suggest testing at 1 Hz.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20936310      PMCID: PMC3377806          DOI: 10.1007/s00586-010-1582-8

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  15 in total

Review 1.  The role of macrophages in osteolysis of total joint replacement.

Authors:  Eileen Ingham; John Fisher
Journal:  Biomaterials       Date:  2005-04       Impact factor: 12.479

2.  Polyethylene wear debris and long-term clinical failure of the Charité disc prosthesis: a study of 4 patients.

Authors:  André van Ooij; Steven M Kurtz; Filip Stessels; Huub Noten; Lodewijk van Rhijn
Journal:  Spine (Phila Pa 1976)       Date:  2007-01-15       Impact factor: 3.468

3.  Preliminary study of the effect of aging following irradiation on the wear of ultrahigh-molecular-weight polyethylene.

Authors:  J Fisher; K L Chan; J L Hailey; D Shaw; M Stone
Journal:  J Arthroplasty       Date:  1995-10       Impact factor: 4.757

4.  Friction moments of large metal-on-metal hip joint bearings and other modern designs.

Authors:  N E Bishop; F Waldow; M M Morlock
Journal:  Med Eng Phys       Date:  2008-03-04       Impact factor: 2.242

5.  Lumbar disk replacement failures: review of 29 patients and rationale for revision.

Authors:  Charles Rosen; P Douglas Kiester; Thay Q Lee
Journal:  Orthopedics       Date:  2009-08       Impact factor: 1.390

6.  The effect of frictional heating and forced cooling on the serum lubricant and wear of UHMW polyethylene cups against cobalt-chromium and zirconia balls.

Authors:  Y-S Liao; H McKellop; Z Lu; P Campbell; P Benya
Journal:  Biomaterials       Date:  2003-08       Impact factor: 12.479

7.  Surface slide track mapping of implants for total disc arthroplasty.

Authors:  Philippe E Paré; Frank W Chan; Sanghita Bhattacharya; Vijay K Goel
Journal:  J Biomech       Date:  2009-01-08       Impact factor: 2.712

8.  Total disc replacement compared to lumbar fusion: a randomised controlled trial with 2-year follow-up.

Authors:  Svante Berg; Tycho Tullberg; Björn Branth; Claes Olerud; Hans Tropp
Journal:  Eur Spine J       Date:  2009-06-09       Impact factor: 3.134

9.  Periprosthetic tissue reactions observed at revision of total intervertebral disc arthroplasty.

Authors:  Ilona M Punt; Jack P M Cleutjens; Thorvald de Bruin; Paul C Willems; Steven M Kurtz; Lodewijk W van Rhijn; Geert Willem H Schurink; André van Ooij
Journal:  Biomaterials       Date:  2009-01-19       Impact factor: 12.479

10.  Complications of artificial disc replacement: a report of 27 patients with the SB Charité disc.

Authors:  André van Ooij; F Cumhur Oner; Ab J Verbout
Journal:  J Spinal Disord Tech       Date:  2003-08
View more
  3 in total

1.  The use of self-mating PEEK as an alternative bearing material for cervical disc arthroplasty: a comparison of different simulator inputs and tribological environments.

Authors:  Tim Brown; Qi-Bin Bao
Journal:  Eur Spine J       Date:  2012-03-14       Impact factor: 3.134

2.  CORR Insights®: Periprosthetic UHMWPE Wear Debris Induces Inflammation, Vascularization, and Innervation After Total Disc Replacement in the Lumbar Spine.

Authors:  Timothy M Wright
Journal:  Clin Orthop Relat Res       Date:  2016-08-17       Impact factor: 4.176

3.  We Need to Talk about Lumbar Total Disc Replacement.

Authors:  Stephen Beatty
Journal:  Int J Spine Surg       Date:  2018-08-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.