Elad Maor1, Antoni Ivorra, James J Mitchell, Boris Rubinsky. 1. Biophysics Graduate Group, Department of Mechanical Engineering, 6124 Etcheverry Hall, University of California, Berkeley, CA 94720, USA. eladmaor@gmail.com
Abstract
PURPOSE: To evaluate the effect of endovascular nonthermal irreversible electroporation (NTIRE) on blood vessels. MATERIALS AND METHODS: Specially made endovascular devices with four electrodes on top of inflatable balloons were used to apply electroporation pulses. Finite element simulations were used to characterize NTIRE protocols that would not induce thermal damage to treated tissues. Right iliac arteries of eight rabbits were treated with 90 NTIRE pulses. Angiograms were performed before and after the procedures. Arterial specimens were harvested at 7 and 35 days. Evaluation included hematoxylin and eosin, elastic von Giessen, and Masson trichrome stains. Immunohistochemistry of selected slides included smooth muscle actin (SMA), proliferating cell nuclear antigen, von Willebrand factor (VWF), and S-100 antigen. RESULTS: At 7 days, all NTIRE-treated arterial segments displayed complete, transmural ablation of vascular smooth muscle cells (VSMC). At 35 days, similar damage to VSMC was noted. In most cases, the elastic lamina remained intact, and endothelial layer regenerated. Occasional mural inflammation and cartilaginous metaplasia were noted. After 5 weeks, there was no evidence of significant VSMC proliferation, with the dominant process being wall fibrosis with regenerated endothelium. CONCLUSIONS: NTIRE can be applied in an endovascular approach. It efficiently ablates vessel wall within seconds and with no damage to extracellular structures. NTIRE has possible applications in many fields of clinical cardiology, including arterial restenosis and cardiac arrhythmias.
PURPOSE: To evaluate the effect of endovascular nonthermal irreversible electroporation (NTIRE) on blood vessels. MATERIALS AND METHODS: Specially made endovascular devices with four electrodes on top of inflatable balloons were used to apply electroporation pulses. Finite element simulations were used to characterize NTIRE protocols that would not induce thermal damage to treated tissues. Right iliac arteries of eight rabbits were treated with 90 NTIRE pulses. Angiograms were performed before and after the procedures. Arterial specimens were harvested at 7 and 35 days. Evaluation included hematoxylin and eosin, elastic von Giessen, and Masson trichrome stains. Immunohistochemistry of selected slides included smooth muscle actin (SMA), proliferating cell nuclear antigen, von Willebrand factor (VWF), and S-100 antigen. RESULTS: At 7 days, all NTIRE-treated arterial segments displayed complete, transmural ablation of vascular smooth muscle cells (VSMC). At 35 days, similar damage to VSMC was noted. In most cases, the elastic lamina remained intact, and endothelial layer regenerated. Occasional mural inflammation and cartilaginous metaplasia were noted. After 5 weeks, there was no evidence of significant VSMC proliferation, with the dominant process being wall fibrosis with regenerated endothelium. CONCLUSIONS:NTIRE can be applied in an endovascular approach. It efficiently ablates vessel wall within seconds and with no damage to extracellular structures. NTIRE has possible applications in many fields of clinical cardiology, including arterial restenosis and cardiac arrhythmias.
Authors: W S Grundfest; F Litvack; J S Forrester; T Goldenberg; H J Swan; L Morgenstern; M Fishbein; I S McDermid; D M Rider; T J Pacala Journal: J Am Coll Cardiol Date: 1985-04 Impact factor: 24.094
Authors: Deling Kong; Luis G Melo; Massimiliano Gnecchi; Lunan Zhang; Gustavo Mostoslavsky; Chong C Liew; Richard E Pratt; Victor J Dzau Journal: Circulation Date: 2004-09-27 Impact factor: 29.690
Authors: A H Schulick; A J Taylor; W Zuo; C B Qiu; G Dong; R N Woodward; R Agah; A B Roberts; R Virmani; D A Dichek Journal: Proc Natl Acad Sci U S A Date: 1998-06-09 Impact factor: 11.205
Authors: Amy R Deipolyi; Alexander Golberg; Martin L Yarmush; Ronald S Arellano; Rahmi Oklu Journal: Diagn Interv Radiol Date: 2014 Mar-Apr Impact factor: 2.630
Authors: Anna J Shangguan; Chong Sun; Bin Wang; Liang Pan; Quanhong Ma; Su Hu; Jia Yang; Aydin Eresen; Yuri Velichko; Vahid Yaghmai; Zhuoli Zhang Journal: Am J Cancer Res Date: 2019-09-01 Impact factor: 6.166
Authors: Hester J Scheffer; Laurien G P H Vroomen; Karin Nielsen; Aukje A J M van Tilborg; Emile F I Comans; Cornelis van Kuijk; Bram B van der Meijs; Janneke van den Bergh; Petrousjka M P van den Tol; Martijn R Meijerink Journal: BMC Cancer Date: 2015-10-24 Impact factor: 4.430