Titanium implants: a removal torque study in osteopenic rabbits.

Carine M Carvalho1, Luiz F Carvalho, Lino J Costa, Marcelo J Sa, Claudia R Figueiredo, Adilio S Azevedo.   

Abstract

CONTEXT: Osteoporosis is a skeletal disorder characterized by low bone mass and microarchitectural deterioration of bone tissue. It may affect the craniomaxillofacial complex and result in less bone-implant contact. AIMS: The objective of this study was to measure the endosseous integration of titanium implants using the removal torque test in low-mineral density experimental animal models.
MATERIALS AND METHODS: Thirty female New Zealand white rabbits were divided into two groups: control (n=14), sham-operated; and test (n=16), ovariectomized. All animals received 2.2 mm Χ 4.0 mm titanium implants in the right tibia, 120 days after ovariectomy or sham surgery. Animals were killed at 7 and 14 weeks of postimplant insertion, when implants were removed by reverse torque rotation using a digital torque meter. Statistical analysis used was Student's t-test. RESULTS AND
CONCLUSION: At the 7-week period, the mean torque values for the control and test groups were 11.6 Ncm and 10.4 Ncm, respectively, with no statistical significance. Implant removal torque analysis showed statistically lower values (P < 0.05) for the test group at the 14-week period (control=16.7 Ncm and test=9.7 Ncm). The results of this study indicate that hormonal privacy compromise implants biomechanical performance.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20930342     DOI: 10.4103/0970-9290.70798

Source DB:  PubMed          Journal:  Indian J Dent Res        ISSN: 0970-9290


  8 in total

Review 1.  Dental implants in patients affected by systemic diseases.

Authors:  N Donos; E Calciolari
Journal:  Br Dent J       Date:  2014-10       Impact factor: 1.626

Review 2.  Animal models for periodontal regeneration and peri-implant responses.

Authors:  Alpdogan Kantarci; Hatice Hasturk; Thomas E Van Dyke
Journal:  Periodontol 2000       Date:  2015-06       Impact factor: 7.589

3.  Low-magnitude high-frequency loading, by whole-body vibration, accelerates early implant osseointegration in ovariectomized rats.

Authors:  Yong-Qiang Liang; Meng-Chun Qi; Jiang Xu; Juan Xu; Hua-Wei Liu; Wei Dong; Jin-Yuan Li; Min Hu
Journal:  Mol Med Rep       Date:  2014-09-23       Impact factor: 2.952

4.  Effects of counter torque and transposition (transfer) of installed implants timing on their integration in dog tibia.

Authors:  Mohammad Reza Karimi; Shima Fathi; Farzin Ghanavati
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

5.  "Reverse torque of 30 Ncm applied to dental implants as test for osseointegration"-a human observational study.

Authors:  Sabrina G Simeone; María Rios; Jeannette Simonpietri
Journal:  Int J Implant Dent       Date:  2016-12-07

6.  Reliability of the Resonance Frequency Analysis Values in New Prototype Transepithelial Abutments: A Prospective Clinical Study.

Authors:  María Guerrero-González; Francesca Monticelli; David Saura García-Martín; Mariano Herrero-Climent; Blanca Ríos-Carrasco; José-Vicente Ríos-Santos; Ana Fernández-Palacín
Journal:  Int J Environ Res Public Health       Date:  2020-09-16       Impact factor: 3.390

7.  A Strontium-Modified Titanium Surface Produced by a New Method and Its Biocompatibility In Vitro.

Authors:  Chundong Liu; Yanli Zhang; Lichao Wang; Xinhua Zhang; Qiuyue Chen; Buling Wu
Journal:  PLoS One       Date:  2015-11-03       Impact factor: 3.240

8.  Development of a quantitative preclinical screening model for implant osseointegration in rat tail vertebra.

Authors:  Sándor Farkasdi; Dávid Pammer; Róbert Rácz; Gergely Hriczó-Koperdák; Bence Tamás Szabó; Csaba Dobó-Nagy; Beáta Kerémi; József Blazsek; Frederic Cuisinier; Gang Wu; Gábor Varga
Journal:  Clin Oral Investig       Date:  2018-10-29       Impact factor: 3.573

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.