The flow characteristics and oil mist spillages of wall-mounted and jet-isolated range hoods were studied experimentally. Flow patterns were examined using a laser-light, sheet-assisted, smoke flow visualization technique. Spillages were diagnosed by the locally averaged tracer gas concentration test method. Tracer gas concentration test results correlated well with those of flow visualizations. For the wall-mounted hood, primary leakages occur around the region near the front edge of a countertop due to boundary layer separation, as well as the region just below the lower edge of the side panels of the hood due to the expansion effect of plumes. Increasing the suction flow rate above some critical values may help to reduce leakages out of the lateral planes but would increase spillages around the front edge of the countertop. For the jet-isolated range hood, oil mists spread widely and present unsteady motions with a high degree of turbulence because insufficient free air is allowed to enter the space enclosed by the jets and rear wall. Spillages across the jets into the environment due to turbulent dispersion become significant. Increasing the suction flow rate above some critical values may help to reduce spillages, while increasing the jet velocity would increase turbulent dispersion and thus lead to larger leakages.Entities: