Longitudinal strain and strain rate by tissue Doppler are more sensitive indices than fractional shortening for assessing the reduced myocardial function in asphyxiated neonates.

Eirik Nestaas1, Asbjørn Støylen, Leif Brunvand, Drude Fugelseth.   

Abstract

The function of the heart was studied in 20 asphyxiated term neonates by measuring the longitudinal peak systolic strain and peak systolic strain rate by tissue Doppler in 18 segments of the heart on days 1, 2, and 3 of life. The fractional shortening was assessed at each examination as well. Measurements were compared against measurements in 48 healthy term neonates examined by the same protocol. The function of the heart was lower in the asphyxiated neonates - peak systolic strain (mean (95% confidence interval) -19.4% (-20.4, -18.5), peak systolic strain rate -1.65 (-1.74, -1.56) per second) than in the healthy term neonates (peak systolic strain -21.7% (-22.3, -21.0), peak systolic strain rate -1.78 (-1.84, -1.74) per second; p < 0.001). Fractional shortening was similar in the asphyxiated (29.2% (26.8, 31.5)) and healthy term neonates (29.0% (27.9, 30.1); p = 0.874). The peak systolic strain differed significantly between the asphyxiated and healthy term neonates for the left basal and right basal groups of segments (p < 0.05) but not for the left apical, right apical, septum apical, or septum basal groups of segments. The peak systolic strain rate differed significantly only for the septum apical group of segments. The differences were largest on the second day of life. Measurements were similar in asphyxiated neonates with elevated and normal cardiac troponin T levels. The peak systolic strain and strain rate were in this study more sensitive indices than fractional shortening for assessing the reduced myocardial function in asphyxiated term neonates.

Entities:  

Mesh:

Year:  2010        PMID: 20923594     DOI: 10.1017/S1047951109991314

Source DB:  PubMed          Journal:  Cardiol Young        ISSN: 1047-9511            Impact factor:   1.093


  23 in total

1.  Feasibility and reproducibility of systolic right ventricular strain measurement by speckle-tracking echocardiography in premature infants.

Authors:  Philip Thaler Levy; Mark R Holland; Timothy J Sekarski; Aaron Hamvas; Gautam K Singh
Journal:  J Am Soc Echocardiogr       Date:  2013-07-20       Impact factor: 5.251

Review 2.  Transthoracic echocardiography in the evaluation of pediatric pulmonary hypertension and ventricular dysfunction.

Authors:  Martin Koestenberger; Mark K Friedberg; Eirik Nestaas; Ina Michel-Behnke; Georg Hansmann
Journal:  Pulm Circ       Date:  2016-03       Impact factor: 3.017

3.  Fetal ventricular interactions and wall mechanics during ductus arteriosus occlusion in a sheep model.

Authors:  Jason N Hashima; Vanessa Rogers; Stephen M Langley; Muhammed Ashraf; David J Sahn; Pasi Ohtonen; Lowell E Davis; A Roger Hohimer; Juha Rasanen
Journal:  Ultrasound Med Biol       Date:  2015-02-17       Impact factor: 2.998

4.  Right ventricular performance using myocardial deformation imaging in infants with bronchopulmonary dysplasia.

Authors:  U Haque; C Stiver; B K Rivera; B Richards; N Ma; C L Cua; C V Smith; C H Backes
Journal:  J Perinatol       Date:  2016-10-05       Impact factor: 2.521

Review 5.  Normal ranges of right ventricular systolic and diastolic strain measures in children: a systematic review and meta-analysis.

Authors:  Philip T Levy; Aura A Sanchez Mejia; Aliza Machefsky; Susan Fowler; Mark R Holland; Gautam K Singh
Journal:  J Am Soc Echocardiogr       Date:  2014-02-26       Impact factor: 5.251

6.  Effects of frame rate on two-dimensional speckle tracking-derived measurements of myocardial deformation in premature infants.

Authors:  Aura A Sanchez; Philip T Levy; Timothy J Sekarski; Aaron Hamvas; Mark R Holland; Gautam K Singh
Journal:  Echocardiography       Date:  2014-08-11       Impact factor: 1.724

7.  Non-Invasive Imaging for Congenital Heart Disease: Recent Innovations in Transthoracic Echocardiography.

Authors:  Martin Koestenberger; Mark K Friedberg; William Ravekes; Eirik Nestaas; Georg Hansmann
Journal:  J Clin Exp Cardiolog       Date:  2012-01-22

8.  Effect of birth asphyxia on p wave dispersion.

Authors:  Hamid Amoozgar; Monirosadat Barekati; Nahal Farhani; Narjes Pishva
Journal:  Indian J Pediatr       Date:  2013-05-03       Impact factor: 1.967

9.  Effect of Temporal and Spatial Smoothing on Speckle-Tracking-Derived Strain in Neonates.

Authors:  Umael Khan; Tom R Omdal; Gottfried Greve; Ketil Grong; Knut Matre
Journal:  Pediatr Cardiol       Date:  2021-01-25       Impact factor: 1.655

10.  Speckle tracking derived strain in neonates: planes, layers and drift.

Authors:  Umael Khan; Tom R Omdal; Knut Matre; Gottfried Greve
Journal:  Int J Cardiovasc Imaging       Date:  2021-03-12       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.