Literature DB >> 20890757

Comparison of headless screws used in the treatment of proximal nonunion of scaphoid bone.

Arel Gereli1, Ufuk Nalbantoglu, Ismail Ugur Sener, Barıs Kocaoglu, Metin Turkmen.   

Abstract

Screws with different levels of compression force are available for scaphoid fixation and it is known that the Acutrak screw generates greater compression than the Herbert screw. We retrospectively compared two types of headless compression screw for their effectiveness in the repair of scaphoid nonunion. Twenty-nine cases of proximal scaphoid nonunion were surgically treated with non-vascularised bone graft: the Acutrak screw was used in 17 patients and the cannulated Herbert screw in 12 patients. Wrist range of motion, Mayo wrist score, grip strength and QuickDASH scores were indicators used for the functional evaluation. Radiographic findings were assessed for consolidation of nonunion and signs of arthrosis. The mean follow-up time was 49.2 months (range 12-96). Statistically, there was no significant difference between the Acutrak and Herbert screw types in terms of functional evaluation and time required for consolidation. Greater compression did not influence the functional outcome, consolidation rate or time to consolidation. The need for greater compression in the treatment of proximal scaphoid nonunions is thus questionable because it may increase the risk of proximal fragment communition.

Entities:  

Mesh:

Year:  2010        PMID: 20890757      PMCID: PMC3167405          DOI: 10.1007/s00264-010-1129-y

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  29 in total

1.  Treatment of ununited fractures of the carpal scaphoid by iliac bone grafts and Herbert screw fixation.

Authors:  G Inoue; T Miura
Journal:  Int Orthop       Date:  1991       Impact factor: 3.075

2.  A new vascularized bone graft for scaphoid nonunion.

Authors:  C Zaidemberg; J W Siebert; C Angrigiani
Journal:  J Hand Surg Am       Date:  1991-05       Impact factor: 2.230

3.  Anterior bone grafting and conventional lag screw fixation to treat scaphoid nonunions.

Authors:  D L Fernandez
Journal:  J Hand Surg Am       Date:  1990-01       Impact factor: 2.230

4.  Biomechanical assessment of compression screws.

Authors:  D L Wheeler; S W McLoughlin
Journal:  Clin Orthop Relat Res       Date:  1998-05       Impact factor: 4.176

5.  Treatment of scaphoid nonunions with a vascularized bone graft based on the first dorsal metacarpal artery.

Authors:  A Yuceturk; Z U Isiklar; C Tuncay; R Tandogan
Journal:  J Hand Surg Br       Date:  1997-06

6.  The effect of avascular necrosis on Russe bone grafting for scaphoid nonunion.

Authors:  D P Green
Journal:  J Hand Surg Am       Date:  1985-09       Impact factor: 2.230

7.  Scaphoid nonunion with avascular necrosis of the proximal pole. Treatment with a vascularized bone graft from the dorsum of the distal radius.

Authors:  M I Boyer; H P von Schroeder; T S Axelrod
Journal:  J Hand Surg Br       Date:  1998-10

8.  Difficult wrist fractures. Perilunate fracture-dislocations of the wrist.

Authors:  W P Cooney; R Bussey; J H Dobyns; R L Linscheid
Journal:  Clin Orthop Relat Res       Date:  1987-01       Impact factor: 4.176

9.  Bone-healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression.

Authors:  H T Aro; E Y Chao
Journal:  Clin Orthop Relat Res       Date:  1993-08       Impact factor: 4.176

10.  Herbert screw fixation of scaphoid fractures.

Authors:  S L Filan; T J Herbert
Journal:  J Bone Joint Surg Br       Date:  1996-07
View more
  4 in total

1.  Intramedullary Fixation of Metacarpal Fractures Using Headless Compression Screws.

Authors:  Daniel G Tobert; Melissa Klausmeyer; Chaitanya S Mudgal
Journal:  J Hand Microsurg       Date:  2016-09-21

2.  Pedicled vascularized bone grafts compared with xenografts in the treatment of scaphoid nonunion.

Authors:  S Matić; Č Vučković; A Lešić; I Glišović Jovanović; D Polojac; S Dučić; M Bumbaširević
Journal:  Int Orthop       Date:  2020-09-30       Impact factor: 3.075

3.  Volar Plating versus Headless Compression Screw Fixation of Scaphoid Nonunions: A Meta-analysis of Outcomes.

Authors:  Duncan S Van Nest; Michael Reynolds; Eugene Warnick; Matthew Sherman; Asif M Ilyas
Journal:  J Wrist Surg       Date:  2021-01-03

4.  Can headless screw used in fixation of the scaphoid proximal pole fracture be broken after wrist trauma? An unreported complication of scaphoid surgery.

Authors:  Uğur Bezirgan; Erdinç Acar; Emre Anıl Özbek
Journal:  Jt Dis Relat Surg       Date:  2021-11-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.