Residual seminal vesicle displacement in marker-based image-guided radiotherapy for prostate cancer and the impact on margin design.

Monique H P Smitsmans1, Josien de Bois, Jan-Jakob Sonke, Charles N Catton, David A Jaffray, Joos V Lebesque, Marcel van Herk.   

Abstract

PURPOSE: The objectives of this study were to quantify residual interfraction displacement of seminal vesicles (SV) and investigate the efficacy of rotation correction on SV displacement in marker-based prostate image-guided radiotherapy (IGRT). We also determined the effect of marker registration on the measured SV displacement and its impact on margin design. METHODS AND MATERIALS: SV displacement was determined relative to marker registration by using 296 cone beam computed tomography scans of 13 prostate cancer patients with implanted markers. SV were individually registered in the transverse plane, based on gray-value information. The target registration error (TRE) for the SV due to marker registration inaccuracies was estimated. Correlations between prostate gland rotations and SV displacement and between individual SV displacements were determined.
RESULTS: The SV registration success rate was 99%. Displacement amounts of both SVs were comparable. Systematic and random residual SV displacements were 1.6 mm and 2.0 mm in the left-right direction, respectively, and 2.8 mm and 3.1 mm in the anteroposterior (AP) direction, respectively. Rotation correction did not reduce residual SV displacement. Prostate gland rotation around the left-right axis correlated with SV AP displacement (R(2) = 42%); a correlation existed between both SVs for AP displacement (R(2) = 62%); considerable correlation existed between random errors of SV displacement and TRE (R(2) = 34%).
CONCLUSIONS: Considerable residual SV displacement exists in marker-based IGRT. Rotation correction barely reduced SV displacement, rather, a larger SV displacement was shown relative to the prostate gland that was not captured by the marker position. Marker registration error partly explains SV displacement when correcting for rotations. Correcting for rotations, therefore, is not advisable when SV are part of the target volume. Margin design for SVs should take these uncertainties into account.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20888710     DOI: 10.1016/j.ijrobp.2010.06.026

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  Seminal vesicle interfraction displacement and margins in image guided radiotherapy for prostate cancer.

Authors:  Daisy Mak; Suki Gill; Roxby Paul; Alison Stillie; Annette Haworth; Tomas Kron; Jim Cramb; Kellie Knight; Jessica Thomas; Gillian Duchesne; Farshad Foroudi
Journal:  Radiat Oncol       Date:  2012-08-13       Impact factor: 3.481

2.  Comparison of prostate verification with implanted gold markers in tissue surrounding the prostate and pelvic bony anatomy for external beam radiation therapy following low-dose-rate brachytherapy: a prospective clinical trial.

Authors:  Tomoya Kaneda; Toshio Ohashi; Takashi Hanada; Koji Takenaka; Shuichi Nishimura; Masanori Sakayori; Shinya Sutani; Tetsuo Momma; Naoyuki Shigematsu
Journal:  J Radiat Res       Date:  2020-09-08       Impact factor: 2.724

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.