Literature DB >> 20888055

PTV margins should not be used to compensate for uncertainties in 3D image guided intracavitary brachytherapy.

Kari Tanderup1, Richard Pötter, Jacob Christian Lindegaard, Daniel Berger, André Wambersie, Christian Kirisits.   

Abstract

The planning target volume (PTV) concept has been created within the context of external beam radiotherapy (EBRT). It would be ideal to have a similar approach in brachytherapy (BT) to compensate for uncertainties. However, the BT and EBRT dose distributions are profoundly different, and the role of a PTV concept in BT needs a distinct discussion. The EBRT PTV concept is based on expanding the dose distribution into a homogeneous plateau reaching beyond the CTV. According to basic BT physics, there are significant dose gradients around radioactive source positions, and it is impossible to create homogeneous dose plateaus. This means that PTV margins cannot be directly applied in BT. Application of PTV margins in lateral and anterior-posterior directions can even lead to a significant and overall dose escalation (∼8% per mm margin applied) for the individual patient and for the entire patient population. In the specific direction along the intrauterine tandem, safety margins can partly account for uncertainties, though. In conclusion, safety margins can only be partially applied in intracavitary BT, and it is not recommended to perform PTV delineation. The PTV seems not to be useful for dose reporting, and dose normalisation to PTV is strongly discouraged since it can lead to dose escalation.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20888055     DOI: 10.1016/j.radonc.2010.08.021

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  8 in total

Review 1.  The role of imaging in the management of non-metastatic cervical cancer.

Authors:  Orit Kaidar-Person; Roxolyana Bortnyak-Abdah; Amnon Amit; Alison Berniger; Rahamim Ben-Yosef; Abraham Kuten
Journal:  Med Oncol       Date:  2012-04-25       Impact factor: 3.064

2.  BIT-ART: Multicentric Comparison of HDR-brachytherapy, Intensity-modulated Radiotherapy and Tomotherapy for Advanced Radiotherapy in Prostate Cancer.

Authors:  Anna Rita Alitto; Luca Tagliaferri; Valentina Lancellotta; Andrea D'Aviero; Antonio Piras; Vincenzo Frascino; Francesco Catucci; Bruno Fionda; Christian Staackmann; Simonetta Saldi; Vincenzo Valentini; Gyorgy Kovacs; Cynthia Aristei; Giovanna Mantini
Journal:  In Vivo       Date:  2020 May-Jun       Impact factor: 2.155

3.  Clinical outcome of protocol based image (MRI) guided adaptive brachytherapy combined with 3D conformal radiotherapy with or without chemotherapy in patients with locally advanced cervical cancer.

Authors:  Richard Pötter; Petra Georg; Johannes C A Dimopoulos; Magdalena Grimm; Daniel Berger; Nicole Nesvacil; Dietmar Georg; Maximilian P Schmid; Alexander Reinthaller; Alina Sturdza; Christian Kirisits
Journal:  Radiother Oncol       Date:  2011-08-05       Impact factor: 6.280

4.  Treatment optimization with concurrent SBRT and intracavitary brachytherapy for locally advanced cervical cancer.

Authors:  Bin Wan; Jinyi Lang; Pei Wang; C-M Ma
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

5.  A multicentre comparison of the dosimetric impact of inter- and intra-fractional anatomical variations in fractionated cervix cancer brachytherapy.

Authors:  Nicole Nesvacil; Kari Tanderup; Taran P Hellebust; Astrid De Leeuw; Stefan Lang; Sandy Mohamed; Swamidas V Jamema; Clare Anderson; Richard Pötter; Christian Kirisits
Journal:  Radiother Oncol       Date:  2013-04-18       Impact factor: 6.280

6.  Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (IV): Basic principles and parameters for MR imaging within the frame of image based adaptive cervix cancer brachytherapy.

Authors:  Johannes C A Dimopoulos; Peter Petrow; Kari Tanderup; Primoz Petric; Daniel Berger; Christian Kirisits; Erik M Pedersen; Erik van Limbergen; Christine Haie-Meder; Richard Pötter
Journal:  Radiother Oncol       Date:  2012-01-30       Impact factor: 6.280

7.  Dosimetric impacts of applicator displacements and applicator reconstruction-uncertainties on 3D image-guided brachytherapy for cervical cancer.

Authors:  Joshua Schindel; Winson Zhang; Sudershan K Bhatia; Wenqing Sun; Yusung Kim
Journal:  J Contemp Brachytherapy       Date:  2013-12-18

8.  Reduction of applicator displacement in MR/CT-guided cervical cancer HDR brachytherapy by the use of patient hover transport system.

Authors:  Megan Andrew; Yusung Kim; Timothy Ginader; Brian J Smith; Wenqing Sun; Dongxu Wang
Journal:  J Contemp Brachytherapy       Date:  2018-02-26
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.