Literature DB >> 20884911

Electronic messaging system for communicating important, but nonemergent, abnormal imaging results.

Ronald L Eisenberg1, Kei Yamada, Chun S Yam, Paul W Spirn, Jonathan B Kruskal.   

Abstract

PURPOSE: To evaluate the effectiveness of an electronic messaging system for accurately communicating important, but not emergent, abnormal radiology results to referring physicians.
MATERIALS AND METHODS: The Institutional Review Board deemed this proposal a quality improvement project that did not require formal approval. The electronic messaging system permits radiologists to submit online requests to communicate important, but not emergent, abnormal findings and recommended follow-up to two communications facilitators, who contact referring health care providers by e-mail or telephone. Of 10,510 electronic communications during a 3-year period, a representative sample of 500 communications were selected for detailed analysis. To eliminate bias associated with increased experience with the system, every 20th communication during the 3 years that the messaging system had been functional was examined. Parameters studied included the rate of successful communications with referring physicians, the frequency of these being accomplished within the goal of 48 hours from the time of radiologist submission, and the results of an e-mail survey of physicians to assess their satisfaction with the system.
RESULTS: The radiologic abnormality was successfully communicated to the referring physician in every communication. Overall, a mean of 82.2% ± 3.3 (standard deviation) of communications were accomplished within the goal of 48 hours, with this goal being met in 93.7% ± 2.3 of communications submitted Monday through 3 pm on Thursday. Satisfaction among referring physicians was high (79.0% ± 3.8 satisfied; 5.0% ± 2.0 dissatisfied), especially among those with the most experience with the system.
CONCLUSION: The electronic messaging system communicated important, but not emergent, abnormal radiology results to referring physicians in a timely, accurate, and relatively inexpensive manner. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.10101015/-/DC1. © RSNA, 2010

Mesh:

Year:  2010        PMID: 20884911     DOI: 10.1148/radiol.10101015

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

1.  Does integrating nonurgent, clinically significant radiology alerts within the electronic health record impact closed-loop communication and follow-up?

Authors:  Stacy D O'Connor; Anuj K Dalal; V Anik Sahni; Ronilda Lacson; Ramin Khorasani
Journal:  J Am Med Inform Assoc       Date:  2015-09-02       Impact factor: 4.497

2.  The RADCAT-3 system for closing the loop on important non-urgent radiology findings: a multidisciplinary system-wide approach.

Authors:  Elizabeth H Dibble; David W Swenson; Cynthia Cobb; Timothy J Paul; Andrew E Karn; David C Portelli; Jonathan S Movson
Journal:  Emerg Radiol       Date:  2016-10-14

3.  Communication breakdowns and diagnostic errors: a radiology perspective.

Authors:  Daniel R Murphy; Hardeep Singh; Leonard Berlin
Journal:  Diagnosis (Berl)       Date:  2014-08-19

4.  Difficulties and possibilities in communication between referring clinicians and radiologists: perspective of clinicians.

Authors:  Nabi Fatahi; Ferid Krupic; Mikael Hellström
Journal:  J Multidiscip Healthc       Date:  2019-07-19

5.  Whole-body MRI for preventive health screening: A systematic review of the literature.

Authors:  Robert M Kwee; Thomas C Kwee
Journal:  J Magn Reson Imaging       Date:  2019-04-01       Impact factor: 4.813

6.  The role of a radiology electronic notification system in the emergency department setting and its impact on patient care.

Authors:  Lena A Omar; Richard V King; John Pease; Hythem A Omar
Journal:  J Clin Med Res       Date:  2014-05-22

Review 7.  Error and discrepancy in radiology: inevitable or avoidable?

Authors:  Adrian P Brady
Journal:  Insights Imaging       Date:  2016-12-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.