Literature DB >> 20882668

Efficacy and safety of an intraoral electrostimulation device for xerostomia relief: a multicenter, randomized trial.

Frank P Strietzel1, Gloria I Lafaurie, Gloria R Bautista Mendoza, Ivan Alajbeg, Slavica Pejda, Lea Vuletić, Rubén Mantilla, Denise P Falcão, Soraya C Leal, Ana C Barreto Bezerra, Simon D Tran, Henri A Ménard, Suguru Kimoto, Shaoxia Pan, Rafael A Martín-Granizo, M Lourdes Maniegas Lozano, Susan L Zunt, Cheryl A Krushinski, Dario Melilli, Giuseppina Campisi, Carlo Paderni, Sonia Dolce, Juan F Yepes, Liselott Lindh, Meltem Koray, Gonca Mumcu, Sharon Elad, Itai Zeevi, Beatriz C Aldape Barrios, Rodrigo M López Sánchez, Ben Z Beiski, Andy Wolff, Yrjö T Konttinen.   

Abstract

OBJECTIVE: To evaluate the efficacy and safety of an intraoral electrostimulation device, consisting of stimulating electrodes, an electronic circuit, and a power source, in treating xerostomia. The device delivers electrostimulation through the oral mucosa to the lingual nerve in order to enhance the salivary reflex.
METHODS: The device was tested on a sample of patients with xerostomia due to Sjögren's syndrome and other sicca conditions in a 2-stage prospective, randomized, multicenter trial. Stage I was a double-blind, crossover stage designed to compare the effects of the electrically active device with the sham device, each used for 1 month, and stage II was a 3-month open-label stage designed to assess the long-term effects of the active device. Improvement in xerostomia severity from baseline was the primary outcome measure.
RESULTS: A total of 114 patients were randomized. In stage I, the active device performed better than the sham device for patient-reported xerostomia severity (P<0.002), xerostomia frequency (P<0.05), quality of life impairment (P<0.01), and swallowing difficulty (P<0.02). At the end of stage II, statistically significant improvements were verified for patient-reported xerostomia severity (P<0.0001), xerostomia frequency (P<0.0001), oral discomfort (P<0.001), speech difficulty (P<0.02), sleeping difficulty (P<0.001), and resting salivary flow rate (P<0.01).
CONCLUSION: Our findings indicate that daily use of the device alleviated oral dryness, discomfort, and some complications of xerostomia, such as speech and sleeping difficulties, and increased salivary output. The results show a cumulative positive effect of the device over the period of the study, from baseline to the end of the trial.

Entities:  

Mesh:

Year:  2011        PMID: 20882668     DOI: 10.1002/art.27766

Source DB:  PubMed          Journal:  Arthritis Rheum        ISSN: 0004-3591


  19 in total

Review 1.  Topical and systemic medications for the treatment of primary Sjögren's syndrome.

Authors:  Manuel Ramos-Casals; Pilar Brito-Zerón; Antoni Sisó-Almirall; Xavier Bosch; Athanasios G Tzioufas
Journal:  Nat Rev Rheumatol       Date:  2012-05-01       Impact factor: 20.543

2.  Electrostimulation device provides safeand effective relief of dry mouth.

Authors: 
Journal:  Nat Rev Rheumatol       Date:  2010-12       Impact factor: 20.543

Review 3.  World Workshop on Oral Medicine VI: a systematic review of medication-induced salivary gland dysfunction: prevalence, diagnosis, and treatment.

Authors:  Alessandro Villa; Andy Wolff; Doron Aframian; Arjan Vissink; Jörgen Ekström; Gordon Proctor; Richard McGowan; Nagamani Narayana; Ardita Aliko; Ying Wai Sia; Revan Kumar Joshi; Siri Beier Jensen; Alexander Ross Kerr; Colin Dawes; Anne Marie Lynge Pedersen
Journal:  Clin Oral Investig       Date:  2015-05-22       Impact factor: 3.573

Review 4.  Treatment of primary Sjögren syndrome.

Authors:  Alain Saraux; Jacques-Olivier Pers; Valérie Devauchelle-Pensec
Journal:  Nat Rev Rheumatol       Date:  2016-07-14       Impact factor: 20.543

5.  Vasoactive intestinal peptide/vasoactive intestinal peptide receptor relative expression in salivary glands as one endogenous modulator of acinar cell apoptosis in a murine model of Sjögren's syndrome.

Authors:  V Hauk; M Calafat; L Larocca; L Fraccaroli; E Grasso; R Ramhorst; C Pérez Leirós
Journal:  Clin Exp Immunol       Date:  2011-12       Impact factor: 4.330

Review 6.  Management of primary Sjögren's syndrome: recent developments and new classification criteria.

Authors:  Nicoletta Del Papa; Claudio Vitali
Journal:  Ther Adv Musculoskelet Dis       Date:  2018-01-01       Impact factor: 5.346

7.  Relative Efficacy of Swallowing versus Non-swallowing Tasks in Dysphagia Rehabilitation: Current Evidence and Future Directions.

Authors:  Teresa C Drulia; Christy L Ludlow
Journal:  Curr Phys Med Rehabil Rep       Date:  2013-12

Review 8.  Medication-Induced Xerostomia and Hyposalivation in the Elderly: Culprits, Complications, and Management.

Authors:  Anna Greta Barbe
Journal:  Drugs Aging       Date:  2018-10       Impact factor: 3.923

Review 9.  Interventions for the management of dry mouth: non-pharmacological interventions.

Authors:  Susan Furness; Gemma Bryan; Roddy McMillan; Sarah Birchenough; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2013-09-05

10.  Safety and efficacy of an intra-oral electrostimulator for the relief of dry mouth in patients with chronic graft versus host disease: Case series.

Authors:  Yehuda Zadik; Itai Zeevi; Noa Luboshitz-Shon; Nasri Dakwar; Andy Wolff; Michael Y Shapira; Reuven Or; Sharon Elad
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2014-05-01
View more