PURPOSE: The effects of air cleaners on the removal of airborne indoor allergens, especially house dust mites (HDM), are still controversial. The objective of this study is to evaluate the effect of an air cleaner with an electrostatic filter on the removal of airborne mite allergens.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20879060 PMCID: PMC2995978 DOI: 10.3349/ymj.2010.51.6.918
Source DB: PubMed Journal: Yonsei Med J ISSN: 0513-5796 Impact factor: 2.759
Fig. 1Distribution of airborne particles per size immediately after dispersion of the 150 mg of culture media at the closed chamber. It was expressed with the volume of the particles (A) or number of particles (B) per m3 according to the size of the particles.
Fig. 2Removal efficiency of the split electrostatic and fine mesh mechanical pre-filter air cleaner. The size and number of HDM particles were measured using a dust spectrometer. (A) HDM particles in the size range 10.0 - 12.5 µm. (B) HDM particles in the size range 5.0 - 6.5 µm. (C) HDM particles in the size range 2.0 - 2.5 µm. (D) HDM particles in the size range 0.25 - 0.28 µm. The bars in these figures represent standard error of the mean. HDM, house dust mites.
Fig. 3Removal efficiency of the air cleaner expressed as the percentage removal of airborne HDM particles in the chamber. The baseline value is the concentration of particles immediately after spraying. (A) Removal efficiency after 15 minutes. (B) Removal efficiency after 30 minutes. (C) Removal efficiency after 60 minutes. Black bars in A-C represent the rate of settlement of HDM particles. D shows the fold-increase in HDM removal by the cleaner compared to the natural settlement. The dotted line represents 1 fold indicating natural settlement. Bars in these figures represent standard errors of the mean. *p < 0.05.
Fig. 4CADR values of the electrostatic and fine mesh mechanical pre-filter air cleaner according to the size of airborne particles. CADR values are airborne particle size dependent. The bars in this figure represent standard error of the mean. *p < 0.05. CADR, Clean Air Delivery Rate.
Fig. 5Concentration of Der f 1 in extracts from the air sampling filters installed in a closed chamber with or without air cleaner. The bars in this figure represent standard error of the mean. *p < 0.05.