Literature DB >> 20878971

Manganese enhancement in non-CNS organs.

Li-Wen Lee1, Po-Wah So, Anthony N Price, James R C Parkinson, David J Larkman, Jane Halliday, Simon M Poucher, John A T Pugh, Alan G Cox, Cameron W McLeod, Jimmy D Bell.   

Abstract

Manganese-enhanced magnetic resonance imaging (MEMRI) is a novel imaging technique capable of monitoring calcium influx, in vivo. Manganese (Mn2+) ions, similar to calcium ions (Ca2+), are taken up by activated cells where their paramagnetic properties afford signal enhancement in T(1)-weighted MRI methodologies. In this study we have assessed Mn2+ distribution in mice using magnetization-prepared rapid gradient echo (MP-RAGE) based MRI, by measuring changes in T(1)-effective relaxation times (T(1)-eff), effective R(1)-relaxation rates (R(1)-eff) and signal intensity (SI) profiles over time. The manganese concentration in the tissue was also determined using inductively coupled plasma atomic emission spectrometry (ICP-AES). Our results show a strong positive correlation between infused dose of MnCl2 and the tissue manganese concentration. Furthermore, we demonstrate a linear relationship between R(1)-eff and tissue manganese concentration and tissue-specific Mn2+ distribution in murine tissues following dose-dependent Mn2+ administration. This data provides an optimized MnCl2 dose regimen for an MP-RAGE based sequence protocol for specific target organs and presents a potential 3D MRI technique for in vivo imaging of Ca2+ entry during Ca2+-dependent processes in a wide range of tissues.
Copyright © 2010 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20878971     DOI: 10.1002/nbm.1513

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  4 in total

1.  β-Cell subcellular localization of glucose-stimulated Mn uptake by X-ray fluorescence microscopy: implications for pancreatic MRI.

Authors:  Lara Leoni; Anita Dhyani; Patrick La Riviere; Stefan Vogt; Barry Lai; B B Roman
Journal:  Contrast Media Mol Imaging       Date:  2011 Nov-Dec       Impact factor: 3.161

2.  Dose ranging, expanded acute toxicity and safety pharmacology studies for intravenously administered functionalized graphene nanoparticle formulations.

Authors:  Shruti Kanakia; Jimmy D Toussaint; Sayan Mullick Chowdhury; Tanuf Tembulkar; Stephen Lee; Ya-Ping Jiang; Richard Z Lin; Kenneth R Shroyer; William Moore; Balaji Sitharaman
Journal:  Biomaterials       Date:  2014-05-20       Impact factor: 12.479

3.  Same-session functional assessment of rat retina and brain with manganese-enhanced MRI.

Authors:  David Bissig; Bruce A Berkowitz
Journal:  Neuroimage       Date:  2011-07-01       Impact factor: 6.556

4.  Empirical mathematical model for dynamic manganese-enhanced MRI of the murine pancreas for assessment of β-cell function.

Authors:  Anita H Dhyani; Xiaobing Fan; Lara Leoni; Muhammad Haque; Brian B Roman
Journal:  Magn Reson Imaging       Date:  2012-10-25       Impact factor: 2.546

  4 in total