We report a case of Rumpel-Leede (RL) phenomenon, - acute dermis capillary rupture, secondary to noninvasive blood pressure (NIBP) monitoring in a patient with type 2 diabetes mellitus (DM) and hypertension. The first most likely cause is vascular fragility in microangiopathy as a result of DM and chronic steroid use. The second is the increased venous pressure during cycling of the blood pressure cuff in a hypertensive state. Anesthesiologists need to be aware that acute dermal capillary rupture, although rare, can occur in patients with long-standing DM, hypertension and chronic steroid use.

Entities:  

Keywords:  Hypertension; Noninvasive blood pressure cuff; Rumpel-Leede phenomenon; Steroid; Vascular fragility

Year:  2010        PMID: 20877706      PMCID: PMC2946039          DOI: 10.4097/kjae.2010.59.3.203

Source DB:  PubMed          Journal:  Korean J Anesthesiol        ISSN: 2005-6419


  13 in total

1.  Blood pressure measurement in volunteers with and without padding between the cuff and the skin.

Authors:  L J Archer; A J Smith
Journal:  Anaesthesia       Date:  2001-09       Impact factor: 6.955

2.  Compartment syndrome of the arm: a complication of noninvasive blood pressure monitoring during thrombolytic therapy for myocardial infarction.

Authors:  J Winslow Alford; Mark A Palumbo; Michael J Barnum
Journal:  J Clin Monit Comput       Date:  2002 Apr-May       Impact factor: 2.502

3.  The Rumpel-Leede sign associated with drug-induced erythema multiforme.

Authors:  A S Gross; R J Holloway; R M Fine
Journal:  J Am Acad Dermatol       Date:  1992-11       Impact factor: 11.527

4.  Blood pressure cuff compression injury of the radial nerve.

Authors:  C C Lin; B Jawan; M V de Villa; F C Chen; P P Liu
Journal:  J Clin Anesth       Date:  2001-06       Impact factor: 9.452

5.  Acute radial nerve injury from use of an automatic blood pressure monitor.

Authors:  P E Bickler; A Schapera; C R Bainton
Journal:  Anesthesiology       Date:  1990-07       Impact factor: 7.892

6.  The Rumpel-Leede sign associated with a noninvasive ambulatory blood pressure monitor.

Authors:  W B White
Journal:  JAMA       Date:  1985 Mar 22-29       Impact factor: 56.272

7.  Phlebitis associated with noninvasive 24-hour ambulatory blood pressure monitor.

Authors:  P C Creevy; J F Burris; W J Mroczek
Journal:  JAMA       Date:  1985-11-01       Impact factor: 56.272

Review 8.  Skin necrosis in a critically ill patient due to a blood pressure cuff.

Authors:  M P Devbhandari; Z Shariff; A J Duncan
Journal:  J Postgrad Med       Date:  2006 Apr-Jun       Impact factor: 1.476

9.  [Simple diagnosis of diabetic microangiopathy by means of the tourniquet test].

Authors:  C Rürup; H Stobbe
Journal:  Z Gesamte Inn Med       Date:  1979-12-15

10.  Steroid treatment of idiopathic thrombocytopenic purpura in children. Preliminary results of a randomized cooperative study.

Authors:  J A Sartorius
Journal:  Am J Pediatr Hematol Oncol       Date:  1984
View more
  5 in total

1.  Rumpel-leede phenomenon in a hypertensive lady on amlodipine.

Authors:  Kandan Balamurugesan; Stalin Viswanathan
Journal:  J Clin Diagn Res       Date:  2014-04-15

2.  Rumple-Leede Phenomenon Associated with Leg Massager.

Authors:  Sharad Mutalik; Vasudha Belgaumkar; Yashashree Rasal
Journal:  J Lifestyle Med       Date:  2020-01-31

Review 3.  Recent Advances in Non-Invasive Blood Pressure Monitoring and Prediction Using a Machine Learning Approach.

Authors:  Siti Nor Ashikin Ismail; Nazrul Anuar Nayan; Rosmina Jaafar; Zazilah May
Journal:  Sensors (Basel)       Date:  2022-08-18       Impact factor: 3.847

Review 4.  Advances in Non-Invasive Blood Pressure Monitoring.

Authors:  Xina Quan; Junjun Liu; Thomas Roxlo; Siddharth Siddharth; Weyland Leong; Arthur Muir; So-Min Cheong; Anoop Rao
Journal:  Sensors (Basel)       Date:  2021-06-22       Impact factor: 3.576

5.  Rhabdomyolysis complicating non-invasive blood pressure measurement.

Authors:  Chitra Srinivasan; Balaji Kuppuswamy
Journal:  Indian J Anaesth       Date:  2012-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.