G Mestres1, Z A Zarka, C García-Madrid, V Riambau. 1. Vascular Surgery Division, Department of Cardiovascular Surgery, Thorax Institute, Hospital Clinic, University of Barcelona, Barcelona, Spain. gasparmestres@gmail.com
Abstract
OBJECTIVES: To report the results of long-term follow-up of abdominal aortic aneurysms (AAAs) treated with endografts more than a decade ago. DESIGN: Retrospective analysis of estimated long-term follow-up, mortality and morbidity in terms of complications and re-interventions, using the Kaplan-Meier survival analysis. MATERIALS/ METHODS: Between March 1997 and January 2000, 61 patients with AAA (53 asymptomatic, four symptomatic and three ruptured) were treated with aortic endografts. All preoperative, operative and follow-up data were recorded according to the EUROpean collaborators on Stent graft Techniques for abdominal aortic Aneurysm (EUROSTAR) criteria. RESULTS: The primary technical success rate was 98.4%. The majority of used devices were Vanguard (65.0%), and in a bifurcated configuration (86.7%). At 10-year follow-up, the estimated cumulative follow-up rate was 82.0%; complications occurred in 74.6% of the patients and re-interventions were required in 56.9%. The Vanguard endograft was related to a higher incidence of re-interventions (P=0.012). The combined in-hospital or AAA-related mortality rate was 5.0% at 30 days and 8.2% at a 10-year follow-up (1.8% and 5.0% in elective cases, respectively). CONCLUSIONS: Early abdominal endografts are associated with high incidence of complications (74.6%) and re-interventions (56.9%) at a 10-year follow-up; however, the mortality rate related to the procedure or aneurysm is low (5.0% in elective cases). Early endografts need lifelong strict surveillance.
OBJECTIVES: To report the results of long-term follow-up of abdominal aortic aneurysms (AAAs) treated with endografts more than a decade ago. DESIGN: Retrospective analysis of estimated long-term follow-up, mortality and morbidity in terms of complications and re-interventions, using the Kaplan-Meier survival analysis. MATERIALS/ METHODS: Between March 1997 and January 2000, 61 patients with AAA (53 asymptomatic, four symptomatic and three ruptured) were treated with aortic endografts. All preoperative, operative and follow-up data were recorded according to the EUROpean collaborators on Stent graft Techniques for abdominal aortic Aneurysm (EUROSTAR) criteria. RESULTS: The primary technical success rate was 98.4%. The majority of used devices were Vanguard (65.0%), and in a bifurcated configuration (86.7%). At 10-year follow-up, the estimated cumulative follow-up rate was 82.0%; complications occurred in 74.6% of the patients and re-interventions were required in 56.9%. The Vanguard endograft was related to a higher incidence of re-interventions (P=0.012). The combined in-hospital or AAA-related mortality rate was 5.0% at 30 days and 8.2% at a 10-year follow-up (1.8% and 5.0% in elective cases, respectively). CONCLUSIONS: Early abdominal endografts are associated with high incidence of complications (74.6%) and re-interventions (56.9%) at a 10-year follow-up; however, the mortality rate related to the procedure or aneurysm is low (5.0% in elective cases). Early endografts need lifelong strict surveillance.
Authors: Hyun Beom Kim; Young Ho Choi; Young Ho So; Seung-Kee Min; Hyo-Cheol Kim; Young Il Kim; Jae Hyung Park; Jin Wook Chung Journal: J Korean Med Sci Date: 2012-10-02 Impact factor: 2.153
Authors: Jun Ho Yang; Jong Woo Kim; Ho Chul Choi; Hyun Oh Park; In Seok Jang; Chung Eun Lee; Seong Ho Moon; Jeong Hun Byun; Jun Young Choi Journal: Vasc Specialist Int Date: 2017-12-31