Literature DB >> 20875528

Spectroradiometric and spectrophotometric translucency of ceramic materials.

Ho-Nam Lim1, Bin Yu, Yong-Keun Lee.   

Abstract

STATEMENT OF PROBLEM: The spectroradiometer (SR) was introduced as an alternative instrument to the spectrophotometer (SP) for measuring color in dentistry. No published studies were identified on the SR-based translucency of clinically simulated dental ceramics that closely reflect clinical conditions. Furthermore, it is unclear whether there is a correlation between SR- and SP-based translucency values.
PURPOSE: The purpose of this study was to compare the translucency parameter (TP) of core, veneer, and layered ceramics determined by an SR, and to determine the correlations in TPs measured by an SR and a reflection SP.
MATERIAL AND METHODS: Seven A2 shade core ceramics and corresponding A2 and A3 shade veneer ceramics were fabricated with a layered thickness of 1.5 mm. The color of core, veneer, and A2- and A3-layered ceramics was measured over white and black backgrounds by an SR with 2 measuring apertures of 2.63 and 5.25 mm in diameter, and also by an SP (n=7). TP values were calculated and the differences in SR (5.25)-based TP values of the layered ceramics were analyzed with 2-way ANOVA with the fixed factors of shade designation and type of ceramic core (α=.05). The influence of the brand on the TP values of core, veneer, and A2- and A3-layered ceramics was also analyzed with 1-way ANOVA. Correlation analysis and paired t test were performed for the SR- and SP-based TP values (α=.05).
RESULTS: SR (5.25)-based TP values of layered ceramics ranged from 4.4 to 12.5, and were influenced by the type but not by the shade designation. SR-based TP values of core, veneer, and A2- and A3-layered ceramics were influenced by the brand. SR- and SP-based TP values were highly correlated (r=0.982 to 0.987, P<.01), although TP values based on SR measurement were significantly higher (P<.05).
CONCLUSIONS: SR measurements showed significantly different translucency for different types of clinically simulated ceramic specimens. TP values measured by the SR and the SP were significantly different but highly correlated.
Copyright © 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20875528     DOI: 10.1016/S0022-3913(10)60131-X

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  17 in total

1.  The color change in artificial white spot lesions measured using a spectroradiometer.

Authors:  Younju Kim; Ho-Hyun Son; Keewook Yi; Hae-Young Kim; Jinsoo Ahn; Juhea Chang
Journal:  Clin Oral Investig       Date:  2012-01-27       Impact factor: 3.573

Review 2.  Resin-composite blocks for dental CAD/CAM applications.

Authors:  N D Ruse; M J Sadoun
Journal:  J Dent Res       Date:  2014-10-24       Impact factor: 6.116

3.  Analysis of Translucency Parameter of Glass-Ceramics Fabricated by Different Techniques.

Authors:  Karla Ledić; Igor Majnarić; Slađana Milardović; Stipe Špalj; Sanja Štefančić; Ketij Mehulić
Journal:  Acta Stomatol Croat       Date:  2015-03

4.  Effect of Potassium Aluminum Sulfate Application on the Viability of Fibroblasts on a CAD-CAM Feldspathic Ceramic before and after Thermocycling.

Authors:  Gülce Çakmak; Canan Akay; Mustafa Borga Donmez; Emre Mumcu; Handan Sevim Akan; Rafat Sasany; Samir Abou-Ayash; Burak Yilmaz
Journal:  Materials (Basel)       Date:  2022-06-15       Impact factor: 3.748

5.  Effect of stain brand and shade on color stability of stains applied on a CAD-CAM feldspathic ceramic.

Authors:  Rafat Sasany; Burak Yilmaz
Journal:  Odontology       Date:  2022-01-18       Impact factor: 2.885

6.  The Effect of two Shading Techniques on Value of Zirconia-Based Crowns.

Authors:  Ahmad Hassan Ahangari; Kianoosh Torabi Ardakani; Farideh Mahdavi; Mahshid Torabi Ardakani
Journal:  J Dent (Shiraz)       Date:  2015-06

7.  Comparison of the translucency of shaded zirconia all-ceramic systems.

Authors:  Sevcan Kurtulmus-Yilmaz; Mutahhar Ulusoy
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

8.  Translucency and color match with a shade guide of esthetic brackets with the aid of a spectroradiometer.

Authors:  Yong-Keun Lee; Yu Bin
Journal:  Dental Press J Orthod       Date:  2016 Mar-Apr

9.  Effect of abutment shade, ceramic thickness, and coping type on the final shade of zirconia all-ceramic restorations: in vitro study of color masking ability.

Authors:  Seon-Hee Oh; Seok-Gyu Kim
Journal:  J Adv Prosthodont       Date:  2015-10-28       Impact factor: 1.904

10.  Translucency of monolithic and core zirconia after hydrothermal aging.

Authors:  Salma M Fathy; Abeer A El-Fallal; Salwa A El-Negoly; Abu Baker El Bedawy
Journal:  Acta Biomater Odontol Scand       Date:  2015-11-09
View more