Literature DB >> 20874741

Echocardiographic prediction of patent ductus arteriosus in need of therapeutic intervention.

S Harling1, I Hansen-Pupp, A Baigi, E Pesonen.   

Abstract

AIM: To evaluate the efficacy of various echocardiographic markers in predicting a patent ductus arteriosus (PDA) in need of treatment.
METHODS: Forty-five preterm infants with a mean (SD) gestational age of 27.7 (1.9) weeks underwent echocardiography at a postnatal age of 24 ± 6 and 72 ± 6 h. Four echocardiographic markers were studied: ductus diameter, ductal flow Doppler curves, the left atrial to aortic root (LA/Ao) ratio and Doppler pixels representing ductal shunting.
RESULTS: Twenty-eight infants had a PDA with a detectable left-to-right shunt. Of these, 12 (43%) were treated for a shunt through the PDA. Ductal diameter was the most accurate echocardiographic marker when it came to predicting a significant shunt, with a sensitivity of 89%, a specificity of 70%, a positive likelihood ratio of 2.97 and a negative likelihood ratio of 0.16 at the age of 72 h. The efficacy of the method at 72 h of age was 84%. The corresponding efficacy of the pulsatile Doppler curve was 72%, percentage of green colour pixels 63% and the LA/Ao ratio 53%.
CONCLUSION: Ductus diameter appears to be the most important variable in determining the need for therapeutic intervention for PDA in preterm infants.
© 2010 The Author(s)/Acta Paediatrica © 2010 Foundation Acta Paediatrica.

Entities:  

Mesh:

Year:  2010        PMID: 20874741     DOI: 10.1111/j.1651-2227.2010.02027.x

Source DB:  PubMed          Journal:  Acta Paediatr        ISSN: 0803-5253            Impact factor:   2.299


  10 in total

1.  Functional echocardiography in staging for ductal disease severity : role in predicting outcomes.

Authors:  Arvind Sehgal; Eldho Paul; Samuel Menahem
Journal:  Eur J Pediatr       Date:  2012-10-11       Impact factor: 3.183

Review 2.  Patent ductus arteriosus: are current neonatal treatment options better or worse than no treatment at all?

Authors:  Ronald I Clyman; James Couto; Gail M Murphy
Journal:  Semin Perinatol       Date:  2012-04       Impact factor: 3.300

Review 3.  Patent ductus arteriosus in preterm infants: is early transcatheter closure a paradigm shift?

Authors:  P Vali; S Lakshminrusimha; A Pelech; M Underwood; F Ing
Journal:  J Perinatol       Date:  2019-09-27       Impact factor: 3.225

Review 4.  Patent ductus arteriosus in preterm infants: do we have the right answers?

Authors:  Hesham Abdel-Hady; Nehad Nasef; Abd Elazeez Shabaan; Islam Nour
Journal:  Biomed Res Int       Date:  2013-12-23       Impact factor: 3.411

5.  Hemodynamic Effects on Systemic Blood Flow and Ductal Shunting Flow after Loading Dose of Intravenous Caffeine in Preterm Infants according to the Patency of Ductus Arteriosus.

Authors:  Jihye Hwang; Yu Seon Kim; Jeong Hee Shin; Byung Min Choi
Journal:  J Korean Med Sci       Date:  2018-01-22       Impact factor: 2.153

6.  Development of a Diagnostic Clinical Score for Hemodynamically Significant Patent Ductus Arteriosus.

Authors:  Annemarie Kindler; Barbara Seipolt; Antje Heilmann; Ursula Range; Mario Rüdiger; Sigrun Ruth Hofmann
Journal:  Front Pediatr       Date:  2017-12-22       Impact factor: 3.418

7.  Effects of prophylactic oral ibuprofen on the closure rate of patent ductus arteriosus in premature infants.

Authors:  Yanjie Ding; Xuan Wang; Yanqiu Wu; Hui Li; Jiaju Xu; Xiaoliang Wang
Journal:  Medicine (Baltimore)       Date:  2018-09       Impact factor: 1.817

Review 8.  Objective Assessment of Physiologic Alterations Associated With Hemodynamically Significant Patent Ductus Arteriosus in Extremely Premature Neonates.

Authors:  Aparna Patra; Pratibha S Thakkar; Majd Makhoul; Henrietta S Bada
Journal:  Front Pediatr       Date:  2021-02-25       Impact factor: 3.418

9.  Predictive Tool for Closure of Ductus Arteriosus with Pharmacologic or Surgical Treatment in Preterm Infants.

Authors:  TaiXiang Liu; Zheng Chen; XiaoLu Ma; LiPing Shi
Journal:  Pediatr Cardiol       Date:  2021-09-12       Impact factor: 1.655

Review 10.  Application of NPE in the assessment of a patent ductus arteriosus.

Authors:  David van Laere; Bart van Overmeire; Samir Gupta; Afif El-Khuffash; Marilena Savoia; Patrick J McNamara; Christoph E Schwarz; Willem P de Boode
Journal:  Pediatr Res       Date:  2018-07       Impact factor: 3.756

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.