Literature DB >> 20873780

Asymmetrical emitter geometries for increased range of stable electrospray flow rates.

E Jane Maxwell, Xuefei Zhong, David D Y Chen.   

Abstract

Because electric field distribution is determined by emitter size and shape, sprayer tip geometry determines the optimum liquid flow rate that can be processed by the electrospray ionization interface. Electric field is the highest at the sharpest edge of an electrode; therefore, for a beveled tip, the field is highest at the very tip, and for a conventional symmetrically tapered tip, the field is the highest around the rim of the electrode. Electrospray performance as a function of flow rate was investigated using both continuous infusion and peak-based analysis. The sharpest symmetrical emitter gave the most stable electrospray ionization (ESI) at flow rates ≤0.10 μL/min, while beveled emitters provided significantly better performance at expanded flow rates up to 1 μL/min. The use of beveled emitters offers the potential for increased versatility in electrospray ionization interfaces.

Entities:  

Year:  2010        PMID: 20873780     DOI: 10.1021/ac1017953

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

Review 1.  Recent advances in coupling capillary electrophoresis-based separation techniques to ESI and MALDI-MS.

Authors:  Xuefei Zhong; Zichuan Zhang; Shan Jiang; Lingjun Li
Journal:  Electrophoresis       Date:  2013-12-05       Impact factor: 3.535

2.  Enhanced nebulization efficiency of electrospray mass spectrometry: improved sensitivity and detection limit.

Authors:  Anneli Kruve; Ivo Leito; Koit Herodes; Asko Laaniste; Rünno Lõhmus
Journal:  J Am Soc Mass Spectrom       Date:  2012-09-22       Impact factor: 3.109

3.  Recent advances in the analysis of therapeutic proteins by capillary and microchip electrophoresis.

Authors:  Jessica S Creamer; Nathan J Oborny; Susan M Lunte
Journal:  Anal Methods       Date:  2014-07-08       Impact factor: 2.896

4.  Membrane-based emitter for coupling microfluidics with ultrasensitive nanoelectrospray ionization-mass spectrometry.

Authors:  Xuefei Sun; Ryan T Kelly; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2011-06-22       Impact factor: 6.986

5.  Improving the comprehensiveness and sensitivity of sheathless capillary electrophoresis-tandem mass spectrometry for proteomic analysis.

Authors:  Yueju Wang; Bryan R Fonslow; Catherine C L Wong; Aleksey Nakorchevsky; John R Yates
Journal:  Anal Chem       Date:  2012-10-05       Impact factor: 6.986

6.  In-line separation by capillary electrophoresis prior to analysis by top-down mass spectrometry enables sensitive characterization of protein complexes.

Authors:  Xuemei Han; Yueju Wang; Aaron Aslanian; Bryan Fonslow; Beth Graczyk; Trisha N Davis; John R Yates
Journal:  J Proteome Res       Date:  2014-11-21       Impact factor: 4.466

7.  Sheathless capillary electrophoresis-tandem mass spectrometry for top-down characterization of Pyrococcus furiosus proteins on a proteome scale.

Authors:  Xuemei Han; Yueju Wang; Aaron Aslanian; Marshall Bern; Mathieu Lavallée-Adam; John R Yates
Journal:  Anal Chem       Date:  2014-10-30       Impact factor: 6.986

8.  A novel microchip-based imaged CIEF-MS system for comprehensive characterization and identification of biopharmaceutical charge variants.

Authors:  Scott Mack; Don Arnold; Greg Bogdan; Luc Bousse; Lieza Danan; Vladislav Dolnik; MaryAnn Ducusin; Eric Gwerder; Chris Herring; Morten Jensen; Jennifer Ji; Steve Lacy; Claudia Richter; Ian Walton; Erik Gentalen
Journal:  Electrophoresis       Date:  2019-11-08       Impact factor: 3.535