Microfluidic chip-capillary electrophoresis for two orders extension of adjustable upper working range for profiling of inorganic and organic anions in urine.

Wen Peng Guo1, Kap Man Lau, Ying Sing Fung.   

Abstract

To meet the need for onsite monitoring of urine anions, a microfluidic chip-capillary electrophoresis device was designed, fabricated and tested to extend the upper CE working range for an enhancement up to 500 fold (100 fold for sample dilution and 5 folds for CE injection) in order to analyze highly variable anionic metabolites in urine samples. Capillaries were embedded between two PMMA plates with laser-fabricated microchannel patterns to produce the microfluidic chip-capillary electrophoresis to perform standard/sample dilution and CE injection with adjustable dilution ratios. A circular ferrofluid valve was incorporated on-chip to perform cleanup and conditioning, mixing and dilution, injection and CE separation. Under optimized conditions, a complete assay for four samples can be achieved within an hour for 15 anions commonly found in urines. Satisfactory working ranges (0.005-500 mM) and low detection limits (0.5-6.5 μM based on S/N =2) are obtained with satisfactory repeatability (RSD, n=5) 0.52-0.87% and 4.1-6.5% for migration time and peak area, respectively. The working ranges with two orders adjustable upper extension are adequate to cover all analytes concentrations commonly found in human urine samples. The device fabricated shows sufficiently large experimentally verifiable enhancement factor to meet the application requirements. Its reliability was established by more than 94% recoveries of spiked standards and agreeable results from parallel method comparison with conventional ion chromatography method. The extension of the upper CE working range enables flexible onsite dilution on demand, a quick turn-around of results, and a low-cost device suitable for bedside monitoring of patients under critical conditions for metabolic disorders.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20872610     DOI: 10.1002/elps.201000297

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  4 in total

1.  Integrated microfluidic chip for rapid DNA digestion and time-resolved capillary electrophoresis analysis.

Authors:  Che-Hsin Lin; Yao-Nan Wang; Lung-Ming Fu
Journal:  Biomicrofluidics       Date:  2012-03-15       Impact factor: 2.800

2.  Experimental and numerical analysis of high-resolution injection technique for capillary electrophoresis microchip.

Authors:  Chin-Lung Chang; Jik-Chang Leong; Ting-Fu Hong; Yao-Nan Wang; Lung-Ming Fu
Journal:  Int J Mol Sci       Date:  2011-06-03       Impact factor: 5.923

3.  Microfluidic mixing: a review.

Authors:  Chia-Yen Lee; Chin-Lung Chang; Yao-Nan Wang; Lung-Ming Fu
Journal:  Int J Mol Sci       Date:  2011-05-18       Impact factor: 5.923

4.  Detection and Quantification of Inorganic and Organic Anions in Natural, Potable, and Wastewaters in Northern New York Using Capillary Zone Electrophoresis and Indirect UV Detection.

Authors:  Lara Varden; Britannia Smith; Fadi Bou-Abdallah
Journal:  J Chromatogr Sep Tech       Date:  2017-05-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.