Literature DB >> 20870589

Presence of potential bacterial pathogens in a municipal drinking water supply system.

T Felföldi1, Tímea Tarnóczai, Z G Homonnay.   

Abstract

The quality of drinking water is a major public concern, but the detection of most potential pathogens is not always included in drinking water hygienic monitoring or is only assessed with highly biased cultivation-based methods. In this study, the occurrence of Pseudomonas aeruginosa and Legionella spp. was examined with taxon-specific PCRs in samples taken at ten points of a municipal drinking water supply system in three months. Sequence analysis confirmed the positivity of samples and revealed a diverse community of legionellae. The results showed that chlorination was an important and effective disinfection method against pathogenic bacteria in drinking water, but pathogenic bacteria could reoccur in the system farther away from the chlorination point. No strong correlation was found between the presence of the investigated potentially pathogenic bacteria and the measured abiotic and biotic parameters within the investigated range. It is hypothesized that instead of physicochemical parameters, the main factors influencing the presence of pathogens in the drinking water were rather the composition of the microbial community, the biotic interactions between individual non-pathogenic and pathogenic microorganisms (competition or promotion of growth) and the structure of biofilm grown on the inner surface of the supply system.

Entities:  

Mesh:

Year:  2010        PMID: 20870589     DOI: 10.1556/AMicr.57.2010.3.2

Source DB:  PubMed          Journal:  Acta Microbiol Immunol Hung        ISSN: 1217-8950            Impact factor:   2.048


  3 in total

1.  Evaluation of methods for the extraction of DNA from drinking water distribution system biofilms.

Authors:  Chiachi Hwang; Fangqiong Ling; Gary L Andersen; Mark W LeChevallier; Wen-Tso Liu
Journal:  Microbes Environ       Date:  2011-11-10       Impact factor: 2.912

2.  Prevalence and antibiotic resistance of Pseudomonas aeruginosa in water samples in central Italy and molecular characterization of oprD in imipenem resistant isolates.

Authors:  Giuditta Fiorella Schiavano; Elisa Carloni; Francesca Andreoni; Silvia Magi; Maria Chironna; Giorgio Brandi; Giulia Amagliani
Journal:  PLoS One       Date:  2017-12-06       Impact factor: 3.240

Review 3.  Legionella Occurrence beyond Cooling Towers and Premise Plumbing.

Authors:  David Otto Schwake; Absar Alum; Morteza Abbaszadegan
Journal:  Microorganisms       Date:  2021-12-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.