Literature DB >> 20870241

Relationship between the particle size distribution of commercial fully porous and superficially porous high-performance liquid chromatography column packings and their chromatographic performance.

D Cabooter1, A Fanigliulo, G Bellazzi, B Allieri, A Rottigni, G Desmet.   

Abstract

The separation efficiency and kinetics of several commercial HPLC particle types (both fully porous and superficially porous) have been investigated using a pharmaceutical weakly basic N-containing compound as a test molecule. A strong trend between the particle size distribution (PSD) of the particles and the typically employed "goodness of packing"-parameters was observed. The relative standard deviation of the PSD of the tested particles ranged between 0.05 and 0.2, and in this range, a near linear relationship between the A-term constant, the h(min)-value and the minimal separation impedance was found. The experimental findings hence confirm the recent observations regarding the relationship between the narrow PSD of the recently commercialized porous-shell particles and their superior efficiency and kinetic performance. The outcome also suggests that the performance of the current generation of fully porous particle columns could be significantly improved if the PSD of these particles could be reduced.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20870241     DOI: 10.1016/j.chroma.2010.09.008

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  7 in total

1.  Superficially porous particles with 1000Å pores for large biomolecule high performance liquid chromatography and polymer size exclusion chromatography.

Authors:  Brian M Wagner; Stephanie A Schuster; Barry E Boyes; Taylor J Shields; William L Miles; Mark J Haynes; Robert E Moran; Joseph J Kirkland; Mark R Schure
Journal:  J Chromatogr A       Date:  2017-01-31       Impact factor: 4.759

2.  Development of a carbon clad core-shell silica for high speed two-dimensional liquid chromatography.

Authors:  Changyub Paek; Yuan Huang; Marcelo R Filgueira; Alon V McCormick; Peter W Carr
Journal:  J Chromatogr A       Date:  2012-01-11       Impact factor: 4.759

3.  Kinetic performance comparison of fully and superficially porous particles with sizes ranging between 2.7 μm and 5 μm: Intrinsic evaluation and application to a pharmaceutical test compound.

Authors:  K Broeckhoven; D Cabooter; G Desmet
Journal:  J Pharm Anal       Date:  2012-12-25

4.  Core-Shell in Liquid Chromatography: Application for Determining Sulphonamides in Feed and Meat Using Conventional Chromatographic Systems.

Authors:  Antonio Armentano; Simona Summa; Sonia Lo Magro; Pasquale D'Antini; Carmen Palermo; Marilena Muscarella
Journal:  Ital J Food Saf       Date:  2016-12-06

5.  Theoretical Analysis of Efficiency of Multi-Layer Core-Shell Stationary Phases in the High Performance Liquid Chromatography of Large Biomolecules.

Authors:  Szabolcs Horváth; Fabrice Gritti; Róbert Kormány; Krisztián Horváth
Journal:  Molecules       Date:  2019-08-06       Impact factor: 4.411

6.  Mass spectrometry detection of basic drugs in fast chiral analyses with vancomycin stationary phases.

Authors:  Hongyue Guo; M Farooq Wahab; Alain Berthod; Daniel W Armstrong
Journal:  J Pharm Anal       Date:  2018-08-09

7.  The Way to Ultrafast, High-Throughput Enantioseparations of Bioactive Compounds in Liquid and Supercritical Fluid Chromatography.

Authors:  Omar H Ismail; Simona Felletti; Chiara De Luca; Luisa Pasti; Nicola Marchetti; Valentina Costa; Francesco Gasparrini; Alberto Cavazzini; Martina Catani
Journal:  Molecules       Date:  2018-10-20       Impact factor: 4.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.