Literature DB >> 20870208

Nodule size and fine-needle aspiration biopsy: diagnostic challenges for thyroid malignancy.

Stefano Rausei1, Gianlorenzo Dionigi, Francesco Frattini, Patrizia Castano, Andrea Leotta, Francesca Rovera, Luigi Boni, Luigi Bartalena, Renzo Dionigi.   

Abstract

BACKGROUND: To investigate the relationship between nodule size and malignancy and the correlation between the dimensional parameter and fine-needle aspiration biopsy (FNAB) in patients with a nodular goiter.
METHODS: Histological data of 415 patients who underwent thyroidectomy were used to estimate the actual nodule size and the difference between the diameter of the nodular lesion and the included tumor (intranodular peritumoral tissue [IPT]). FNAB was performed in 338 patients, and its predictive role was evaluated in comparison with histology.
RESULTS: The histology revealed 207 cases of thyroid malignancy. The mean nodule size was significantly larger in benign disease compared with malignant. Only age and FNAB malignant category were independently associated with malignancy. The IPT showed a trend toward a statistically significant association with FNAB malignant category.
CONCLUSIONS: Nodule size does not appear to be a reliable parameter to improve the clinical management of a nodular goiter because of a high variability between size of nodular area and tumor diameter.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20870208     DOI: 10.1016/j.amjsurg.2010.03.008

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  3 in total

1.  Does Tumor Size Influence the Diagnostic Accuracy of Ultrasound-Guided Fine-Needle Aspiration Cytology for Thyroid Nodules?

Authors:  Do Hoon Koo; KwangSeop Song; Hyungju Kwon; Dong Sik Bae; Ji-Hoon Kim; Hye Sook Min; Kyu Eun Lee; Yeo-Kyu Youn
Journal:  Int J Endocrinol       Date:  2016-09-27       Impact factor: 3.257

2.  Evaluation the Relationship Between Thyroid Nodule Size with Malignancy and Accuracy of Fine Needle Aspiration Biopsy (FNAB).

Authors:  Gholamali Godazandeh; Zahra Kashi; Sadegh Zargarnataj; Mehran Fazli; Robab Ebadi; Ensiyeh Hajializadeh Kerdabadi
Journal:  Acta Inform Med       Date:  2016-11-01

3.  Ultrasound Radiomics Nomogram to Diagnose Sub-Centimeter Thyroid Nodules Based on ACR TI-RADS.

Authors:  Wenwu Lu; Di Zhang; Yuzhi Zhang; Xiaoqin Qian; Cheng Qian; Yan Wei; Zicong Xia; Wenbo Ding; Xuejun Ni
Journal:  Cancers (Basel)       Date:  2022-10-03       Impact factor: 6.575

  3 in total