Literature DB >> 20869865

An integrated microfluidic loop-mediated-isothermal-amplification system for rapid sample pre-treatment and detection of viruses.

Chih-Hung Wang1, Kang-Yi Lien, Ting-Yu Wang, Tzong-Yueh Chen, Gwo-Bin Lee.   

Abstract

This study presents a novel automatic assay for targeted ribonucleic acid (RNA) extraction and a one-step reverse transcription loop-mediated-isothermal-amplification (RT-LAMP) process for the rapid detection of viruses from tissue samples by utilizing an integrated microfluidic system. By utilizing specific probe-conjugated magnetic beads, target RNA samples can be specifically recognized and hybridized onto the surface of the magnetic beads which are mixed with whole tissue lysates, followed by the synthesis of complementary deoxyribonucleic acid (cDNA) and isothermal amplification of target genes simultaneously with the incorporation of two specific primer sets. The nervous necrosis virus (NNV), the most common aquaculture pathogen, with a mortality rate in infected fish ranging from 80% to 100%, has been selected to verify the performance of the developed miniature system. Experimental results showed that the sensitivity of the integrated microfluidic LAMP system is about 100-fold higher when compared to a conventional one-step reverse-transcript polymerase chain reaction (RT-PCR) process. Significantly, the entire protocol from sample pre-treatment to target gene amplification can be completed within 60 min in an automatic manner without cross-reactions with other tested virus, bacteria and eukaryotic cells. Consequently, this integrated microfluidic LAMP system may provide a powerful platform for rapid purification and detection of virus samples. Copyright Â
© 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20869865     DOI: 10.1016/j.bios.2010.08.083

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  24 in total

Review 1.  Sample pretreatment and nucleic acid-based detection for fast diagnosis utilizing microfluidic systems.

Authors:  Jung-Hao Wang; Chih-Hung Wang; Gwo-Bin Lee
Journal:  Ann Biomed Eng       Date:  2011-12-07       Impact factor: 3.934

2.  Integrated microfluidic chip for rapid DNA digestion and time-resolved capillary electrophoresis analysis.

Authors:  Che-Hsin Lin; Yao-Nan Wang; Lung-Ming Fu
Journal:  Biomicrofluidics       Date:  2012-03-15       Impact factor: 2.800

3.  A negative-pressure-driven microfluidic chip for the rapid detection of a bladder cancer biomarker in urine using bead-based enzyme-linked immunosorbent assay.

Authors:  Yen-Heng Lin; Ying-Ju Chen; Chao-Sung Lai; Yi-Ting Chen; Chien-Lun Chen; Jau-Song Yu; Yu-Sun Chang
Journal:  Biomicrofluidics       Date:  2013-03-07       Impact factor: 2.800

4.  Rapid detection of live methicillin-resistant Staphylococcus aureus by using an integrated microfluidic system capable of ethidium monoazide pre-treatment and molecular diagnosis.

Authors:  Yu-Hsin Liu; Chih-Hung Wang; Jiunn-Jong Wu; Gwo-Bin Lee
Journal:  Biomicrofluidics       Date:  2012-09-10       Impact factor: 2.800

5.  Microfluidic platform for isolating nucleic acid targets using sequence specific hybridization.

Authors:  Jingjing Wang; Kenneth Morabito; Jay X Tang; Anubhav Tripathi
Journal:  Biomicrofluidics       Date:  2013-07-29       Impact factor: 2.800

6.  Isolation and amplification of mRNA within a simple microfluidic lab on a chip.

Authors:  Sarah J Reinholt; Arne Behrent; Cassandra Greene; Ayten Kalfe; Antje J Baeumner
Journal:  Anal Chem       Date:  2013-12-13       Impact factor: 6.986

7.  One-Way Particle Transport Using Oscillatory Flow in Asymmetric Traps.

Authors:  Jaesung Lee; Mark A Burns
Journal:  Small       Date:  2018-01-29       Impact factor: 13.281

8.  Visual detection and evaluation of latent and lytic gene expression during Epstein-Barr virus infection using one-step reverse transcription loop-mediated isothermal amplification.

Authors:  Xiaoying Liu; Jingfeng Tang; Man Wang; Qiang Ma; Yefu Wang
Journal:  Int J Mol Sci       Date:  2013-12-09       Impact factor: 5.923

9.  A newly developed paper embedded microchip based on LAMP for rapid multiple detections of foodborne pathogens.

Authors:  Mimi Zhang; Jinfeng Liu; Zhiqiang Shen; Yongxin Liu; Yang Song; Yu Liang; Zhende Li; Lingmei Nie; Yanjun Fang; Youquan Zhao
Journal:  BMC Microbiol       Date:  2021-06-28       Impact factor: 3.605

10.  Static self-directed sample dispensing into a series of reaction wells on a microfluidic card for parallel genetic detection of microbial pathogens.

Authors:  Robert D Stedtfeld; Yen-Cheng Liu; Tiffany M Stedtfeld; Tanja Kostic; Maggie Kronlein; Onnop Srivannavit; Walid T Khalife; James M Tiedje; Erdogan Gulari; Mary Hughes; Brett Etchebarne; Syed A Hashsham
Journal:  Biomed Microdevices       Date:  2015-10       Impact factor: 2.838

View more