Literature DB >> 20868433

Comparison of the reliability of laser Doppler flowmetry, pulse oximetry and electric pulp tester in assessing the pulp vitality of human teeth.

H Karayilmaz1, Z Kirzioğlu.   

Abstract

This study was designed to evaluate and compare the reliability of laser Doppler flowmetry (LDF), pulse oximetry (PO) and electric pulp tester (EPT) for assessing the pulpal status as a vitality test method by calculating their sensitivity, specificity and predictive values. Data were collected from 59 pairs of maxillary anterior teeth (38 pairs of central, 21 pairs of lateral incisors) in 51 patients (range 12-18years, mean age 14·6±1·73years, 28 women, 23 men). The teeth with complete endodontic fillings constituted the study group, and the healthy, contralateral teeth of the same patients were constituted the control group. The calculated sensitivity was 0·915 for the EPT and 0·813 for the PO. And the specificity of EPT was 0·881 and PO was 0·949. The difference between the LDF values obtained from the study, and control group was statistically significant (P=0·0001). The findings of this study indicated that LDF can reliably discriminate the vitality of the teeth with a sensitivity and specificity of 1·0 for this sample. Laser Doppler flowmetry was found to be a more reliable and effective method than PO and EPT of assessing the pulpal status of human teeth.
© 2010 Blackwell Publishing Ltd.

Entities:  

Mesh:

Year:  2010        PMID: 20868433     DOI: 10.1111/j.1365-2842.2010.02160.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  13 in total

1.  [Study on using laser Doppler flowmetry to determine the pulpal blood flow of immature maxillary incisors].

Authors:  Ma Ninghu; Xiao Gang; Zhang Yuanyuan; Zhang Lin; He Shuyang; Dai Shanshan; Li Yangcheng; Guo Qingyu
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2017-10-01

2.  The use of laser Doppler flowmetry in paediatric dentistry.

Authors:  H Roeykens; R De Moor
Journal:  Eur Arch Paediatr Dent       Date:  2011-04

3.  How standard deviation contributes to the validity of a LDF signal: a cohort study of 8 years of dental trauma.

Authors:  Herman J J Roeykens; Peter De Coster; Wolfgang Jacquet; Roeland J G De Moor
Journal:  Lasers Med Sci       Date:  2019-05-16       Impact factor: 3.161

4.  The use of dental pulp tests in children with dental trauma: a national survey of the British Society of Paediatric Dentistry's members.

Authors:  N Ghouth; M S Duggal; H Nazzal
Journal:  Br Dent J       Date:  2019-02-01       Impact factor: 1.626

5.  Fiber-based laser speckle imaging for the detection of pulsatile flow.

Authors:  Caitlin Regan; Bruce Y Yang; Kent C Mayzel; Julio C Ramirez-San-Juan; Petra Wilder-Smith; Bernard Choi
Journal:  Lasers Surg Med       Date:  2015-08       Impact factor: 4.025

6.  Reference values for pulp oxygen saturation as a diagnostic tool in endodontics: a systematic review and meta-analysis.

Authors:  Paula Lambert; Sergio Augusto Quevedo Miguens; Caroline Solda; Juliana Tomaz Sganzerla; Leandro Azambuja Reichert; Carlos Estrela; Fernando Branco Barletta
Journal:  Restor Dent Endod       Date:  2020-10-05

7.  Efficiency of new custom-made pulse oximeter sensor holder in assessment of actual pulp status.

Authors:  Krishnamachari Janani; P Ajitha; Raghu Sandhya; Haripriya Subbaiyan; Jerry Jose
Journal:  J Family Med Prim Care       Date:  2020-07-30

8.  Multidisciplinary treatment options of tooth avulsion considering different therapy concepts.

Authors:  Eckehard Kostka; Simon Meissner; Christian H Finke; Manlio Mandirola; Saskia Preissner
Journal:  Open Dent J       Date:  2014-10-22

9.  Detection of Pulpal Blood Flow In Vivo with Pulse Oximetry in Dogs.

Authors:  Jessica Riehl; Scott J Hetzel; Christopher J Snyder; Jason W Soukup
Journal:  Front Vet Sci       Date:  2016-05-20

10.  Doppler flowmetry as a tool of predictive, preventive and personalised dentistry.

Authors:  Liudmila Yu Orekhova; Anna A Barmasheva
Journal:  EPMA J       Date:  2013-08-28       Impact factor: 6.543

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.